FELLER ENGINEERING MCS Скачать руководство пользователя страница 2

Long-lasting and

reliable

2

3

A 3-sided LED light band indicates the opera�ng
status, which can be seen from a distance. Green
means that everything is ok. Yellow signals non-
cri�cal devia�ons from normal opera�on, while red
indicates errors or cri�cal devia�ons.

Short circuit proof outputs

External heat sink

16A outputs

The

intelligent

electronics

detect short circuits when
switching on and thus prevent

the affected components from
becoming defec�ve due to
excessive currents.

The external heat sinks ensure
con�nuous heat dissipa�on.

This maximizes the service life
of the electronics.

Each individual output of the
hot runner controllers is capa-
ble of supplying up to 16A. A

special

assignment

of

the

outputs

for

nozzles

or

manifolds is not necessary.

Tiltable display

Service friendly design

3-sided LED light band

Power wiring 2,5 mm²

The �ltable display ensures an op�mum reading
angle and thus reduces incorrect entries. Even when
the display is �lted, the display electronics are 100%
protected against accidental contact.

The power cards are easily replaceable without
opening the device.

The fuses are accessible from the outside and can be
quickly replaced if necessary.

The maximum hea�ng current of 16A is guaranteed
even at increased temperature inside the device.
This is ensured by the robust power wiring with
2.5mm² wire cross-sec�on. In addi�on, only plug
contacts are used that are designed for 16A even at
elevated

�����t

temperatures.

Содержание MCS

Страница 1: ...MCS Hot Runner Controller Precise and Convenient Process Control www fellereng de en Uncompromisingly simple and intuitive...

Страница 2: ...t runner controllers is capa ble of supplying up to 16A A special assignment of the outputs for nozzles or manifolds is not necessary Tiltable display Service friendly design 3 sided LED light band Po...

Страница 3: ...er interface with icons and clearly visible touch fields white ensure intui ve and self explanatory opera on A green background means that a func on is selected A brief descrip on of each func on can...

Страница 4: ...rm an in depth analysis based on the data The mold check tests the wiring of sensors and heaters and is par cularly useful when se ng up a new mold The mold check detects swapped sensors heaters or co...

Страница 5: ......

Страница 6: ...r polarity sensor voltage heater current load short circuit heater interrup on temperature devia ons output level fault current fuse triac relay Timer switch outputs on and off automa cally at specifi...

Страница 7: ...reen In the event of a warning or alarm the display changes to yellow or red The controller can also be switched to standby via an external control signal Fast and precise control High quality electro...

Страница 8: ...oup zones Mold check Gentle heating Sequential heatiing Boost Standby Combined heating Controller network up to 360 zones MCS MCS e Overvoltage protection for sensors Star Delta switching User levels...

Страница 9: ...able electrically insulated per zone 1x hea ng 230V AC switching Control me phase angle pulse package 10 ms at 50 Hz 8 3 ms at 60 Hz Current per zone max 16 A with 80 switch on dura on per zone Minimu...

Страница 10: ...Dimensions 18 19 Tabletop devices 30 36 Zones Large units on rollers 42 to 120 zones...

Страница 11: ...FELLER ENGINEERING GmbH Carl Zeiss Str 14 63322 R dermark Germany Tel 49 0 6074 8949 0 Fax 49 0 6074 8949 49 www fellereng de en E Mail info fellereng de...

Отзывы: