Integrated
Service & Support
6
7
Troubleshooting made easy
etc.
Chart recorder
Service file
Mold check
Event list
The chart recorder is used to analyze the control
behavior of zones by displaying the �me course of
the process values setpoint, actual value and output
level in a curve diagram.
The diagram can be saved as a screenshot for further
analysis.
The service file contains technical data that provides
valuable informa�on for error analysis. It is helpful
when a malfunc�on cannot be solved right away and
therefore technical support has to be called in.
Generated with one click, the file can then be
forwarded by e-mail to Technical Support, who can
perform an in-depth analysis based on the data.
The mold check tests the wiring of sensors and
heaters and is par�cularly useful when se�ng up a
new mold.
The mold check detects swapped sensors, heaters or
connectors, reversed sensor polarity and sensor
short circuit.
The result can be saved in a protocol.
All changes of state of the controller, whether faults
or changes of se�ngs, are recorded chronologically
in an event list.
With this complete documenta�on, processes can be
op�mized and errors can be tracked.
When a malfunc�on occurs, the user receives
precise instruc�ons in words and pictures on how to
proceed with troubleshoo�ng. By clicking on the
arrow bu�ons
the instruc�ons can be
displayed step by step.
This allows troubleshoo�ng to be carried out
extremely efficiently, thus keeping down�mes to a
minimum.
In the example, the fault "Fuse Defec�ve" is present.