Relay check failure 

CAN data loss

Host data loss

Synchronization data loss

The firmware version of 
each inverter is not the same.

The inverter Settings are 
inconsistent

Parallel installation is 
abnormal

Parallel negative power 
protection

EEPROM failure

DSP1 communication failure 

DSP2 communication failure 

1.Update all inverter firmware to the same version.
2.Check the version of each inverter via LCD setting and 
make sure the CPU versions are same. If not, please contact 
your installer to provide the firmware to update.
3.After updating, if the problem still remains, please contact 
your installer.

Restart the unit, if the error happens again, please return
to repair center.

1.Check if communication cables are connected well and
restart the inverter.
2.If the problem remains, please contact your installer.

1.Through the LCD control button on the inverter, the 
parameters of the machine are set to the same as those 
of other machines.
2.If the problem persists, contact the after-sales service

Contact after-sales service for installation technical guidance

Restart the unit, if the error happens again, please return to 
repair center.

Restart the unit, if the error happens again, please return to 
repair center.

Restart the unit, if the error happens again, please return to 
repair center.

Restart the unit, if the error happens again, please return to 
repair center.

42

43

44

45

46

47

48

49

50

51

52

Appendix

Model 

IVGM5048 

Battery Voltage Range

Max. charging and discharging current

Max. charging and discharging power

Battery type

Battery Input Data

40V~60V   

100A/100A   

Max. recommended PV power

Max. PV voltage

Start voltage

PV voltage range

MPPT voltage range

MPPT Voltage Range for Full Load

Nominal voltage

Max. input current

Max. shorted curent

Number of MPP trackers / 
strings per MPP tracker

DC Input Data (PV side)

6500W

550V

130V

90V~550V 

100V~500V

360V   

15A/15A   

18A/18A   

 2/1   

Nominal Input Voltage

Input Voltage Range

Nominal grid frequency

Max. input current

Max. Charge Current

Max. AC output power

AC Output Rated Current 

Max. output current

Max. Continuous AC Passthrough

Power factor

Displacement power factor

THDI

Grid Data

230Vac

184~264.5Vac*

50/60Hz* 

40A

100A

5000W

21.7A

25A

30A

>0.99

0.8leading…0.8lagging 

<3%

IVGM4648 

Li-Ion /Lead-acid

4600W

5000W

6000W

200V~500V

200V~500V

4600W 

20A 

25A 

Hybrid solar inverter   

Hybrid solar inverter  

Содержание IVGM4648

Страница 1: ...Hybrid solar inverter 358 010244 02 IVGM4648 5048 ...

Страница 2: ...RICAL CONNECTION 4 1 PV Connection 4 2 Battery Connection 4 3 On Grid Back Up Connection 4 4 Smart Meter CT Connection 4 5 DRMS Connection 4 6 Lithium Battery Communication 4 7 Installation of WiFi module 4 8 Wiring System 5 Display and operation 5 1 Operation and Display Panel 5 2 LCD Display Icons 5 3 Base information Page 6 Warning Code Table 7 Troubleshooting 8 Appendix 2 2 3 4 5 5 6 6 8 9 9 1...

Страница 3: ...n explosion Please strictly follow installation procedure when you want to disconnect AC or DC terminals Please refer to Installation section of this manual for the details Grounding instructions this inverter should be connected to a permanent grounded wiring system Be sure to comply with local requirements and regulation to install this inverter Never cause AC output and DC input short circuited...

Страница 4: ...pe Make life full of hope Mode 3 When grid fails the system automatically switches to Back Up mode The Back Up load can be supported by PV and battery Mode 4 There is no PV the battery is low and the battery is charged through the grid Make life full of hope Make life full of hope 03 04 1 Figure 2 2 2 Inverter dimensions 1 Inverter Indicators 2 LCD display 3 Button 4 Battery connection port 5 PV i...

Страница 5: ...ansion Bolts Meter CT 4 7 8 3 3 Installation Environment Choose a dry clean and tidy place convenient for installation Ambient temperature range 25 60 Relative humidity 0 100 non condensed Install in a well ventilated place No flammable or explosive materials close to inverter The AC overvoltage category of inverter is category III Maximum altitude 2000m 1 2 3 4 5 6 7 8 2 pairs Figure 3 1 1 Packin...

Страница 6: ... direct sunlight or badweather like snow rain lightning etc 3 4 Mounting The inverter is suitable for mounting on concrete or other non combustible surface only Step 1 Please use the mounting bracket as a template to drill 4 holes in the right positions 10mm in diameter and 80mm in depth Use M8 expansion bolts in accessory box and fix the mounting With a 12mm drill bracket onto the wall tightly Th...

Страница 7: ...p 1 Prepare PV positive and negative power cables Figure 4 1 1 pv cables and pv plugs Step 2 Connect PV cables to PV connectors See Figure 4 1 2 Figure 4 1 2 PV cables to PV connectors PV cables must be tightly crimped into the connectors For Amphenol connector the limit buckle cannot be pressed There will be a click sound if connectors are inserted correctly into PV plugs NOTE Step 3 Screw the ca...

Страница 8: ...are shown as below Battery Terminal Cable Figure 4 3 1 Install AC cables for the inverter Don t connect the PE wire wrong Table 4 3 1 Recommended table of AC circuit breakers INVERTER MODEL AC BREAKER SPECIFIFICATION IVGM4648 5048 40A 230V 2P The absence of AC breaker on back up side will lead to inverter damage if an electrical short circuit happens on back up side NOTE 1 On the AC side the indiv...

Страница 9: ...lar inverter Hybrid solar inverter RUN COM R P Figure 4 3 6 Install ac connection terminals Table 4 4 1 Smart Meter LED Indications STATUS OFF ON Blinking Run Green Com Red R P Red Red The instrument is not running Negative power The instrument is running normally The instrument is in communication status The instrument is not communicating Negative value indicator lamp Positive power NO Function ...

Страница 10: ... remote shutdown function in European countries in compliance with Australia and New Zealand safety requirements or European countries Inverter integrates control logic and provides an interface for DRMS The DRMS is not provided by inverter manufacturer Detailed connection of DRMS Remote Shutdown are shown below Step 1 Screw this plate off from the inverter See Figure 4 6 1 Figure 4 5 1 DRMS inter...

Страница 11: ... white Orange Green white Blue Blue white Green Brown white Brown Function VCC COM GND RS485 B1 RS485 A1 CANL1 CANH1 Hybrid solar inverter Hybrid solar inverter Make life full of hope Figure 4 5 5 RJ45 interface Table 4 6 1 Port pin allocation table Function DRM1 5 DRM2 6 DRM3 7 DRM4 8 REFGEN COM DRMO Step 3 2 For Remote Shutdown Run the cable through the steel plate Then wire from pins 5 and 6 Ta...

Страница 12: ...UP or DOWN button as below page you can see the parameters of SOC battery pack units and other informations in the communication system LCD will be rolled these parameters or informations automatically 3 Configure battery type to lithium battery on the app And then LCD will show you Li icon Rated Output frequency 50Hz Battery Type Lithium batt When it displays b50 means BMS doesn t allow inverter ...

Страница 13: ...P L1 L2 L3 kWh VA Hz 888 OUTPUTBATBMS L1 L2 L3 kWh VA Hz 888 88ERROR S M L3 L2 L1 METER PV1 PV2 Hold on the ESC button last for 3S to turn off the inveter Hold on the ENTER button last for 3S to turn on the inveter Indicates Lithium battery type Indicates communication is built between inverter and battery 5 2 LCD Display Icons Indicates load level by 1 25 26 50 51 75 and 76 100 Hybrid solar inver...

Страница 14: ...age The base information Indicates communication is built between inverter and meter 54 0V 40A CPU software version is 1100 CPU software version Hybrid solar inverter Hybrid solar inverter PV1 PV1 PV2 Pv2 450V PV1 450V PV2 PV1 Pv2 ...

Страница 15: ...rn to repair center Leakage current sensor failed 39 Hybrid solar inverter Hybrid solar inverter 7 Troubleshooting This chapter describes the fault alarm and fault code for quick troubleshooting Table 7 1 Fault code PV voltage is too high Over current happen at PV port Battery voltage is too high Over current happen at Battery Abnormal LLC Over current happen at Buckboost Reduce the number of Pv m...

Страница 16: ...start the unit if the error happens again please return to repair center Restart the unit if the error happens again please return to repair center Restart the unit if the error happens again please return to repair center Restart the unit if the error happens again please return to repair center 42 43 44 45 46 47 48 49 50 51 52 Appendix Model IVGM5048 Battery Voltage Range Max charging and discha...

Страница 17: ... Style Warranty Grid Regulation Safety Regulation EMC Net Weight Gross Weight Product Dimension Package Dimension General Data 4600VA 4600W 5000VA 5000W 25 C 60 C 45 Derating IP65 100 Nature 2000m RS232 RS485 CAN RS485 WiFi GPRS LCD LED Wall mounted 10 years VDE AR N 4105 G99 1 EN50549 1 CEI 0 21 AS 4777 2 NRS 097 2 1 IEC 62109 1 2 IEC 62040 1 EN61000 6 1 EN61000 6 3 Features Support WiFi for mobi...

Отзывы: