Fig 3
(1)Housing Assembly
(3)Photocontrol
(4)2” Screws
(5)Wire Nuts
(6)M6 Nuts
(7)M6 Screws
(8)Cover Plate
(2)LED Bulb
LED LUMINAIRE - IMPORTANT SAFETY INSTRUCTIONS
(9)Handle
Recommend use the diameter 1.5”
Trouble Shooting Guide
If this fixture fails to operate properly, use the guide below to diagnose and correct the problem.
Verify that power is turned on at switch and breaker.
Verify that fixture is wired properly.
Verify that line voltage is correct.
Test if Photocontrol works properly.
The photocontrol in this fixture is designed to turn on fixture light at low light levels.
If light does not come on or stays on:
Test if Photocontrol works properly:
Cover Photocontrol - Light should come on.
Shine a flashlight into Photocontrol - Light should go off.
If fixture cycles on and off:
Light reflecting back off any surrounding surfaces enters the photocontrol.
To correct problem, reposition the fixture or eliminate reflective surface.
Pole Mount Option (Fig 3)
1. Mount arm assembly in desired location
firmly.
2. Unscrew the M6 Screws (7) from handle,
remove the cover plate (8), assemble the
handle to the housing assembly.
3. Pass fixture wires into one opening on
vertical cover plate (8). Reassemble the
cover plate (8) to handle with M6 Screws
(7) and nuts (6).
4. Feed supply wires up through mounting
arm, use wire nuts (5) to connect neutral,
line and grounding wires (black/white/
green-yellow). Push the wires and
connectors into arm.
5. Move the housing assembly toward arm
until there is no gap between the arm and
the vertical cover plate (8).
6. Secure the M6 Screws (7) and nuts (6)
of cover plate (8) firmly.
7. Install the LED bulb (2).
MODEL 73995