6. Removal
C-SC_CSSM
Version 1.0
2019-07-05
All rights reserved by FEIN, especially in case of property rights applications.
FEIN retains all rights of disposal, such as copying and circulation
.
Page
21
of
45
Removing the armature
1.
Remove the bearing bush (1).
2.
Pull off the grooved ball bearing (2).
3.
Remove the disc (3).
4.
Remove the insulating ring (4).
Tools:
- Drawing-off socket cap
- Chuck cone 19 mm
1
2
3
4