Grinding
34130561060
Printed in Germany
Inspection following repairs
C-SC_CSSM
Version 1.0_Template 1.0
01.12.2020
Page
84
of
84
All rights reserved by FEIN, especially in case of property rights applications.
FEIN retains all rights of disposal, such as copying and circulation.
10 Inspection following repairs
A visual and functional check as well as a professional electrical safety test must always be performed after
carrying out repair and maintenance work. The regulations and legal requirements applicable in the
respective country apply.
Minimum tests recommended for this type of machine:
Always: Visual inspection
Speed check
Insert tool
Testing
(e. g., demo material 1 87 20 198 00 0)
Mains-operated machines:
Electrical safety test
If restart protection is available:
Check restart protection
Brake function available:
Brake function check