Internal system faults

F.935

Stack error

  UserSTack or SystemStack overflowed

  Possible software error due to recursive invocations (e.g.

profile)

F.960

Wrong parameter checksum

  New EPROM version with different parameters

  Controller not yet initialized

F.961

Checksum from calibration
values etc.

  New EPROM version with different EEPROM structure

  Controller not yet initialized

F.962

Converter parameters not
plausible

  New EPROM version

  Controller not yet initialized

F.963

Ramp parameters not
plausible

  New EPROM version

  Controller not yet initialized

F.964

Program version /
manufacturer code

  New EPROM version

  Controller not yet initialized

F.970

Plausibility Param.block error

  New EPROM version

  Controller not yet initialized

  Some parameter is implausible

Содержание TST WUI

Страница 1: ...STARTUP preliminary public B 2005 09 07 WUI_Inbetriebnahme2_GB doc TST WUI Important You must read the function description before operating connecting or starting up door controller ...

Страница 2: ...s and completeness of the information in this document In particular FEIG ELECTRONIC GmbH cannot be held liable for following damages due to faulty or incomplete information Since mistakes can never be completely avoided in spite of our best efforts we always welcome feedback The installation recommendations contained in this document presume favorable surrounding conditions FEIG ELECTRONIC GmbH a...

Страница 3: ...ction 9 4 3 1 Phase Motor connection 9 4 4 Safety edge connection 10 4 5 Limit switch connection 10 5 Putting into operation 11 6 Other connection possibilities 12 6 1 Photo eye 12 6 2 External control device 12 7 Inputs overview 12 8 Outputs overview 13 8 1 Outputs of TST WUI 13 8 2 Outputs of TST RWUI 13 9 General operating instructions for parameterisation 14 10 Functions 15 11 Messages overvie...

Страница 4: ... V DC can increase significantly Here discharge times of up to 2 minutes can occur If the 24 V control system is short circuited or extremely overloaded the switching power supply does not start although the DC bus capacitors are charged The display and LEDs remain dark It is not possible to start the power supply unit until after the short circuit or extreme overload has been resolved After switc...

Страница 5: ... Power supply range for 3 phase current without N 3 x 115 240V 10 50 60Hz corresponds o mains power supply voltage of 115 240V 10 50 60Hz IMPORTANT N must be connected with L2 Power supply range for 3 phase current without N in connection with the option TST WU 0 0 A Supply adjustment 400V 3 x 360 400V 10 50 60Hz Required fuse 3x 10A Type K Power consumption Power supply unit without motor max 30W...

Страница 6: ...95 not condensating Mains cable installation Y the mains cable must only be replaced by the manufacturer or his after sales service or by another qualified person Equipment mobility stationary Protection class Protection class I Equipment type Motor appliance external motor is not part of the delivery from FEIG ELECTRONIC GMBH Vibration low vibration installation e g on a brick wall Protection cla...

Страница 7: ... other damage Damage inside the control system can result in significant consequential damages to the control system and risk of injury to the user Touching the electronic parts especially the components of the processor circuit is forbidden Electronic components can be damaged or destroyed by electrostatic discharge Before opening the casing cover it must be ensured there are no drill filings lyi...

Страница 8: ...ans of a reinforced insulation We recommend at least one additional isolation with a nominal voltage 230 V according to EN 60335 1 for all components which are to be connected to the control system Very high electrostatic charges take place especially for fast operating rollup plastic gates Damage to the control system can result from this voltage discharge Therefore suitable countermeasures must ...

Страница 9: ...ng light 1 N P E A 1 L1 L2 L3 13 A 1 L1 L2 L3 13 L3 L2 L1 K 200 C lose K 200 O pen A T1 T2 T3 14 A 1 T1 T2 T3 14 Figure 5 3 Phase Motor connection 4 3 1 Phase Motor connection M 1 230VAC L PE X10 L3 1 X15 X14 X13 A2 T3 N N T2 T1 PE 14 T2 N T1 T1 T2 T3 T3 14 11 10 A2 12 20 K500 X28 1 21 22 K501 34 X20 32 31 33 36 35 PE PE U2 V1 U1 Magnet voltage K1 Com K1 NO K1 NC K2 Com K2 NO K2 NC Rotating flashi...

Страница 10: ...such as e g Electrical safety edge with 1 2kΩ or 8 2kΩ terminal resistor Dynamic optical systems If one of these types of safety edges is connected when the TST WU gate control system is switched on it will be recognised automatically IMPORTANT If no safety edge is connected automatic closing of the door is not possible It is possible to connect other types of safety edges Please contact the gate ...

Страница 11: ...ase the value for fast gates 4 Set the top limit switch so that it just activates IMPORTANT Limit switch in the end positions must not be run over 5 If required for the type of barrier set the top and bottom EMERGENCY limit switches Connect N C contacts e g in the safety circuit in series with thermopile 6 Go to parameterisation mode by pressing the Å STOP and UP keys and select parameter P 980 Se...

Страница 12: ...3 X24 61 Figure 11 External control device 7 Inputs overview E Stop ext 21 E Stop ext 22 GND GND GND 12V Arm broken Crash GND Dead man Auto 24V GND GND 41 X22 42 44 43 45 X23 52 51 54 53 62 X24 61 63 71 X25 65 64 66 72 74 73 76 75 X26 81 83 82 85 84 86 Si Lei GND GND 24V Limit OPEN Limit CLOSE 24V Photo eye Pull switch OSCS 24V Arm blocked 24V E Stop ext 11 E Stop ext 12 2 3 4 5 6 7 8 9 10 Door sw...

Страница 13: ...A2 12 20 K500 2122 K501 34 X20 32 31 33 36 35 PE PE T3 T2 T1 Abbildung 12 Outputs TST WUI 8 2 Outputs of TST RWUI 214 212 211 213 216 215 218 217 224 222 221 223 226 225 228 227 234 232 231 233 236 235 238 237 K3 K4 K5 K6 K7 K8 K9 K10 K11 K12 K13 K14 Transmission Det 1 V Transmission Det 2 N Open synchrone barrier Stop synchrone barrier Barrier Closed Green traffic light from outside Green traffic...

Страница 14: ... or modified see below display varies according to the selection P Parameter editing for selected parameter 1 Control system in parameterisation mode Display of the desired parameter name P 0 1 0 2 Å STOP short Open the parameter the current parameter value is displayed 5 3 Up Up key for increasing parameter value if the current parameter value in force is changed the decimal positions flash 6 or ...

Страница 15: ...time has run out The time starts when open or close travel has stopped Hold open time and clearance time have higher priority means if one of these times is running the forced closing time is not running This is also the case if the barrier is in the upper position while switching on the controller 0 P Unit Adjustment range Diagnostics Factory setting 920 Eb 1 Eb 2 Eb 7 Eb 8 Ebcl Eb Display error ...

Страница 16: ...e limit switch fault light barrier The pre limit switch for the light barrier remains activated even in the middle end position or upper end position Maintenance counter exceeded F 080 Fault Maintenance is required Service counter has expired Parameters not set F 090 Controller not parameterized The basic parameters P 205 for the TST WUI controller have not yet been set Safety chain faults F 201 I...

Страница 17: ...zed An internal safety edge is connected but deactivated F 374 Safety bar testing failed Pre limit switch for safety edge incorrectly set or defective Processing module defective Safety edge defective F 385 Fault in pre limit switch for safety edge Pre limit switch for turning off the safety edge or reversing after safety edge tripping remains tripped even in the upper end position General hardwar...

Страница 18: ...initialized F 961 Checksum from calibration values etc New EPROM version with different EEPROM structure Controller not yet initialized F 962 Converter parameters not plausible New EPROM version Controller not yet initialized F 963 Ramp parameters not plausible New EPROM version Controller not yet initialized F 964 Program version manufacturer code New EPROM version Controller not yet initialized ...

Страница 19: ...key CLOSE Hd oP Deadman open membrane key OPEN Hd Eu End position Lower reached no further deadman close possible Hd Eo End position Upper reached no further deadman open possible Hd Ao Outside of permitted Eo position no deadman open possible Information messages during Automatic mode I 080 Maintenance required soon service counter nearly expired I 100 Speed by reaching the upper limit switch is ...

Страница 20: ...ed Safety edge general E 360 Activation of internal safety edge E 363 Fault in internal safety edge E 370 Activation of external safety edge E 373 Fault in external safety edge E 379 External safety edge activated but not yet plugged in RC plug in module E 401 RC Channel 1 E 402 RC Channel 2 Induction loop processor plug in module E 501 Detector Channel 1 E 502 Detector Channel 2 ...

Отзывы: