TST
Startup
WUI
FEIG ELECTRONIC GmbH
Page 17 of 20
WUI_Inbetriebnahme2_GB.doc
Faults in the safety chain
F.362
Redundancy failure at
shortcut
•
One of the two channels of the shortcut evaluation is not working
or is not the same with the second one
Æ
control board defective
•
Dynamic optical systeme connected but not programmed
with parameter P.460.
F.363
Interruption on edge input
•
Connection cable defective or not connected
•
Termination resistor incorrect or missing
•
Jumper J600 incorrectly set
F.364
Safety edge testing failed
•
Safety edge was not activated as expected when
requesting a test.
•
The time between request for testing and actual testing not
in agreement
F.365
Redundancy failure at
interruption
•
One of the two channels of the interruption evaluation is not
working or is not the same with the second one
Æ
control board
defective
•
Dynamic optical systeme connected but not programmed
with parameter P.460.
F.366
Too high a pulse frequency
for optical safety edge
•
Defective
optical safety edge
•
Defective input for internal safety edge
•
F.369
Internal safety edge
incorrectly parameterized
•
An internal safety edge is connected but deactivated
F.374
Safety bar testing failed
•
Pre-limit switch for safety edge incorrectly set or defective
•
Processing module defective
•
Safety edge defective
F.385
Fault in pre-limit switch for
safety edge
•
Pre-limit switch for turning off the safety edge or reversing after
safety edge tripping remains tripped even in the upper end
position.
General hardware faults
F.400
Controller hardware reset
detected
•
Excessive noise on supply voltage
•
Internal watchdog tripped
•
RAM
error
Positioning system faults
F.700
Position sensing defective
For mechanical limit switches
:
•
At least one limit switch does not correspond to the
configured active status.
•
An implausible combination of at least 2 active limit
switches
Internal system faults
F.920
Internal 2.5 V reference
voltage incorrect
•
Hardware
defect
F.921
Internal 15 V voltage incorrect
•
Hardware
defect
F.922
E-Stop chain not complete
•
Not all E-STOP inputs are
separately
jumpered although
the entire E-Stop chain is jumpered
•
Redundant checking of the E-Stop chain tripped
F.930
External watchdog incorrect
•
Defective hardware or noise-saturated environment
F.931
ROM error
•
Wrong EPROM code
•
Defective hardware or noise-saturated environment
F.932
RAM error
•
Defective hardware or noise-saturated environment