![Feig Electronic TST FUF2 Series Скачать руководство пользователя страница 75](http://html1.mh-extra.com/html/feig-electronic/tst-fuf2-series/tst-fuf2-series_assembly-instructions-manual_3883607075.webp)
TST
Assembly instructions
FUF2 / FU3F-A/-C/-F
FEIG ELECTRONIC GmbH
Page 75 of 114
TST_FUxF-A-C-F_Montageanleitung_EN_15
Door closes.
Suche Si-Leiste
-xxx Auto zu
The door was recognized in the CLOSE position and the
light lines were taught-in correctly.
! Korrekturfahrt !
xxx Start mit
The subsequent travelling of the gate in automatic mode
adjusts the pre-limit switches and limit switch tapes
automatically.
! Korrekturfahrt !
I615 LL Abgl. ok
7.
Start correction drive by pressing the
OPEN-key.
! Korrekturfahrt !
xxx Start mit
The door opens and is taught-in in its position.
Tor öffnet
I.555 Lern Fahrt
Display in end position OPEN.
Offenh= xxs
I.515 Korr. Fahrt
The door closes automatically after the end of the auto-
close time and then opens and closes independently so
long until the correction movement has been completed.
Tor schließt
I.515 Korr. Fahrt
Offenhalt = xxs
I515 Korr. Fahrt
Display that correction was completed.
Offenh 1= xxs
I.510 Korr. OK
Offenh 1= xxs
Automatik
Door opens.
Tor öffnet
Offenh 1= xxs
The door closes and remains in the end position CLOSE.
Tor schließt
The start up of the light curtain has been successfully
completed.
FEIG ELECTRONIC
xxxx Zyklen
Usually the lower end position CLOSED has to be corrected afterwards. This can be defined
using the following parameters:
•
221:
Correction value end position door CLOSE -> this parameter must be reset
after every new teach-in of all end positions (P.210=5).
•
P.275:
Increment correction after synchronization is finished -> recommended as a fixed
setting for the lower limit position. The value set here must NOT be re-set after the new
teach-in of all end positions.