4.3.3 Ethernet Interface (ID ISC.MRU200i-E)
The Reader has an integrated 10 / 100 base-T network port for an RJ45. Connection is made on
X7. With structured cabling Cat 5 cables should be used. This ensures reliable operation at
10 Mbps or 100 Mbps.
Table 4-5: Ethernet interface pinouts
Terminal
Abbreviation
Description
X7 / Pin 1
TX+
Transmit Data +
X7 / Pin 2
TX-
Transmit Data -
X7 / Pin 3
RX+
Receive Data +
X7 / Pin 4
VETH+
n.c.
X7 / Pin 5
VETH+
n.c.
X7 / Pin 6
RX-
Receive Data -
X7 / Pin 7
VETH-
n.c.
X7 / Pin 8
VETH-
n.c.
The prerequisite for using TCP/IP protocol is that each device has a unique address on the net-
work. All Readers have a factory set IP address..
Table 4-6: Standard configuration of the Ethernet connection
Network
Address
IP-Address
192.168.10.10
Subnet-Mask
255.255.255.0
Port
10001
Note:
The readers must be connected to the network and configured one after the other. Every IP-
Address must be used only one time. Alternatively this configuration can be done with the
asynchronous interface
.