Operating and Display Elements
4.1 LED´s
Table 4-1 shows the configuration of the LED’s.
Name
Description
"RUN"
LED V1 (green)
(Operation indicator)
-
Indicates proper running of the internal Reader software
-
Flashing frequency approx. 1 Hz
“HF”
LED V2 (blue)
(RF communication / EEPROM status)
-
Short flashing indicates communication with a transponder on
the RF interface
-
Flashes alternately with V1 after the reset following a software
update
-
Flashes alternately with V1 if an error in reading the
parameters occurred following a reset
“Host”
LED V3 (yellow)
(Host communication)
-
Short flashing indicates a protocol is being sent to the host.
“Diag.2”
LED V4 (yellow)
(for future applications)
“Diag.1”
LED V5 (red)
(Reader initializing / RF warning)
-
Comes on during Reader initializing following power-on or after
a reset.
-
Comes on when there is a warning in the RF section of the
Reader.
The error type can be read via software using the Reader
Diagnostic command [0x6E].