OBID i-scan
®
Montage / Installation
ID ISC.MR200-A/E
FEIG ELECTRONIC GmbH
Page 45 of 56
M40400-4de-ID-B.doc
E N G L I S H
3.7.2 Relay
A changeover relay is provided.
Terminal
Abbreviation
Description
1
COM
Working contact
2
NC
Normally closed
3
NO
Normally open
Table 3-9: Relay output pinouts
Notes:
•
The relay outputs are configured for max. 24 V DC / 2 A.
•
The relay outputs are intended for switching resistive loads only. If an inductive load is
used, the relay contacts must be protected by means of an external protection circuit.
Fig. 3-11: Internal and possible external wiring of the relay output
ID ISC.MR200
COM
NO
NC
ext.
U
X4
3
2
1