OBID
®
Installation
ID ISC.ANT300/300-A
FEIG ELECTRONIC GmbH
Page 38 of 43
M01001-2de-ID-B.DOC
E N G L I S H
6. Course of the antenna’s magnetic lines of electric flux
Figure 24 shows the field alignment of a simple single loop antenna. This is the most simple and
most frequently used antenna type in the sector of
OBID
i
-scan
. Its size depends highly on the
reading range requirements and the place of application as well as the national limiting values.
Figure 24: course of the magnetic lines of electric flux of a single loop antenna
The working range of an antenna depends very much on the position and alignment of the smart
label. A single loop antenna has the highest range in the centre of the antenna and if the smart
label is aligned parallel to the antennas surface.
Label