7.1. CFG0: Passwords
The parameters of the CFG0 configuration block contain the identification codes to personalize the
Reader for a user to prevent outside access to some features of the Reader. For security reasons
data from this configuration block cannot be read from the host, they are “write-only”. Also the
command
8.3. [0x83] Set Default Configuration (Configuration Reset)
isn’t available for this config-
uration block.
Byte
0
1
2
3
4
5
6
Contents
READER-ID
0x00
0x00
0x00
Default
0x00000000
Byte
7
8
9
10
11
12
13
Contents
0x00
CFG_ACCESS
0x00
0x00
Default
READER-ID: (AccessProtection.Password)
Defines the password with which the host logs into the Reader for a read / write access to
the configuration parameter blocks.
CFG_ACCESS: (AccessProtection.Lock_CFGX)
Defines the Configuration blocks which are accessible only if the user has had a success-
ful login to the Reader.
Byte:
8
9
Bit:
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
CFG No.
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
Byte:
10
11
Bit:
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
0
CFG_NO.
16
17
18
19
20
21
22-
29
30-
35
40-
49
50-
59
60-
62
63
36 37
38
39
0
CFG_NO
The Bit in CFG_NO defines if the access to the configuration block is free or if the
user should login to the Reader to get access to the configuration block.
b0
⇒
Access if free
b1
⇒
Access need a login