OBID i-
scan
®
Installation
ID ISC.ANT1300/680-A/-B
FEIG ELECTRONIC GmbH
Page 33 of 45
M71104-6e-ID-B.doc
4.4.2 Reader Setting for Indicator
The ISOStart software can be used to set the Reader configuration so that relay X11 opens or
closes when a Transponder is read.
Step
Action
Note
1
Start ISOStart Software
2
Sel
ect “Configuration” and
click on “Read” to read the
complete configuration.
3
Operating Mode
Select Buffered Read Mode.
4
Digital IO:
Output Idle Mode: OFF
Idle Flash Mode: 1Hz
Setting Time:
with „Setting Time“ set
time of relay 1 for alarm
duration.
(10 means 1 second)
(e.g. 10 x 100ms)
Assign Relay 1 to antenna
1+2. „True“ means: Relay 1
will be active if the reader
read a valid transponder.
5
Set by clicking on „Apply“.
6
Transponder
If the alarm should occur by
a transponder with valid AFI
byte, you have to configure
the reader as follow:
ISO-15693
– Selection Mask
Set “Enable AFI”
Set the value for the AFI in
field “AFI1” (e.g. 01)