background image

IDENTIFICATION 

ID HyWEAR compact 

3  Introduction

 

 

 

 

Page 10 of 41 

 

 

3  Introduction 

Introduction 

 
3.1  The ID HyWEAR compact 

 

The ID HyWEAR compact is the combination of a small RFID- and barcode scanner and a comfortable, 
ergonomic fingerless glove that allows fingers, hand and arm to move freely. The ID HyWEAR compact is 
easy to use with and without gloves and the exchangeable high-capacity rechargeable battery allows long 
use. It is equipped with the latest wireless technology (Bluetooth, WiFi 2.4G/5G with roaming function), 
clearly visible LEDs, buzzer, vibration function and a robust housing. 
The ID HyWEAR compact is developed and manufactured in Germany. 

 

 

 

3.2  Applications 

 

With hands-free use and wireless connection to the host system, the ID HyWEAR compact is ideal for use in 
baggage handling, warehouse logistics, manufacturing and a variety of other applications. Its small size 
allows work to be carried out even on narrow parts and machines. 

 

 

 

Содержание ID HyWEAR compact

Страница 1: ...IDENTIFICATION H90210 2e ID B USER GUIDE ID HyWEAR compact Hands Free UHF RFID Barcode Scan System...

Страница 2: ...rrors may not be completely avoided we are always grateful for your useful tips The instructions given in this manual are based on advantageous boundary conditions FEIG ELECTRONIC GmbH does not give a...

Страница 3: ...n logistics and assembly of the ID HyWEAR compact It contains step by step instructions that explain the basic functions to make working with the ID HyWEAR compact as easy as possible No prior experie...

Страница 4: ...Applications 10 4 Scope of Delivery 11 5 Product Description 12 5 1 Product Illustration 12 5 2 Intended Use 13 5 3 Approvals 14 5 3 1 Europe CE 14 5 3 2 USA FCC 14 6 Technical Data 15 7 Components 16...

Страница 5: ...Connecting to Host 22 10 3 1 Establishing a WiFi Connection 22 10 3 2 Establishing a Bluetooth Connection 22 10 4 Scanning 23 10 5 Configuration 23 10 6 Powering Down the ID HyWEAR compact 23 10 7 Res...

Страница 6: ...me 29 11 5 WiFi Settings 30 11 5 1 Frequency Band 30 11 5 2 DHCP 30 11 5 3 IP Address 30 11 5 4 Port Number 30 11 5 5 Subnet Mask 31 11 5 6 Gateway Address 31 11 5 7 DNS1 31 11 5 8 DNS2 31 11 5 9 SSID...

Страница 7: ...k Trigger Button 35 11 7 2 Left Button Power Off 35 11 7 3 Right Button Power Off 35 11 7 4 Left Button Function 35 11 7 5 Right Button Function 36 12 Troubleshooting 37 13 Maintenance and Cleaning 38...

Страница 8: ...3 nm Do not crush puncture short circuit or place the LiPo battery in fire or water To reduce the risk of fire or burns do not attempt to open disassemble or service the battery pack Do not expose the...

Страница 9: ...Page 9 of 41 2 Revision History of Documentation Revision History Revision Date Description 2 20 09 2019 Approval for Canada IC removed 1 04 09 2019 FCC and IC approval notice supplemented Illustratio...

Страница 10: ...high capacity rechargeable battery allows long use It is equipped with the latest wireless technology Bluetooth WiFi 2 4G 5G with roaming function clearly visible LEDs buzzer vibration function and a...

Страница 11: ...EAR compact fingerless glove 1 x ID HyWEAR compact scanner unit incl battery 1 x ID HyWEAR compact spare battery 1 x ID HyWEAR Charging Station 1 x Power supply cable for ID HyWEAR Charging Station 1...

Страница 12: ...TION ID HyWEAR compact 5 Product Description Page 12 of 41 5 Product Description Product Description 5 1 Product Illustration Fig 1 Product illustration scanner unit Fig 2 Product illustration fingerl...

Страница 13: ...tion Page 13 of 41 5 2 Intended Use The ID HyWEAR compact is designed to read 1D and 2D barcodes as well as RFID tags in the frequency bands 865 MHz to 868 MHz EU version and 902 MHz to 928 MHz FCC ve...

Страница 14: ...Commission Rules permitting the operation of this device This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These lim...

Страница 15: ...e 93 Interleaved 2of5 Codabar Codablock_F 2D DataMatrix QR Code PDF417 Interfaces WiFi Bluetooth 2 4 GHz 5 GHz IEEE 802 11 a b g n h WPA2 PSK WPA2 Enterprise 5 0 SPP Battery 1000 mAh Lithium Polymer 3...

Страница 16: ...ousing and must not be disassembled 7 2 Mechanical 7 2 1 Fingerless Glove The fingerless glove is made of textile and therefore is durable but still comfortable to wear The fingerless glove can be adj...

Страница 17: ...rside of the scanner unit until it is fixed by the clip 2 Slide the scanner unit into the designated pocket on the top of the fingerless glove and connect the electronics using the two snaps Ensure th...

Страница 18: ...ration possibilities see chapter 11 Configuration Parameters on page 24 9 3 Vibration Feedback By default the vibration feedback is deactivated You can configure the vibration feedback via HyWEAR Conf...

Страница 19: ...rging via ID HyWEAR Charging Station The high quality ID HyWEAR Charging Station is part of the accessories of the ID HyWEAR compact and is supplied with it Up to four batteries can be charged simulta...

Страница 20: ...ate of the inserted battery For the different statuses of the LED see the table below State Description Power LED off The charging station is not supplied with power Power LED blue The charging statio...

Страница 21: ...ble With a suitable adapter you can also charge the device via a power outlet using the USB C cable Fig 5 Charging via USB C 10 2 Powering Up the ID HyWEAR compact To power up the ID HyWEAR compact pr...

Страница 22: ...6 Establishing a WiFi connection For detailed information please refer to the Application Note in the FEIG download area using the following link and login data https www feig de en login Username hy...

Страница 23: ...ter the parameter AUTO POWER OFF default setting 600 s has been lapsed and no button was pressed or if a connection could not be made within 60 s To manually power down the device press either the lef...

Страница 24: ...of 29 bytes and may only consist of printable ASCII characters 0123456789 ABCDEFGHIJKLMNOPQRSTUVWXYZ _ abcdefghijklmnopqrstuvwxyz Possible Values Default Value Unit Reset Required None 11 1 2 Auto Pow...

Страница 25: ...FCC Australia New Zealand 0x34 FCC Brazil 0x44 FCC Israel 0x54 FCC Japan 0x64 FCC Malaysia 0x06 EU Europe 0x16 EU Asia Arabia 0x26 EU Russia 0x36 EU Africa 0x46 EU India 0x56 EU Morocco Default Value...

Страница 26: ...ansponder command It starts after the reader has received a new command At the latest after the TR RESPONSE TIME has elapsed the reader will send an answer protocol In this case current commands betwe...

Страница 27: ...he engine from which data is to be read If two engines are selected the second engine is used only when the first engine timed out The default value depends on the version of the reader Possible Value...

Страница 28: ...Soft 11 3 6 Input Events Logical Name OperatingMode ScanMode DataSelector InputEvents Description This configuration flag defines if input states button and trigger states will be part of the scan eve...

Страница 29: ...face Bluetooth PIN Description Defines the Bluetooth PIN for pairing The PIN can have a length of up to 15 characters and may only consist of printable ASCII characters 0123456789 ABCDEFGHIJKLMNOPQRST...

Страница 30: ...able_DHCP Description Enables or disables DHCP for WiFi connection If DHCP is disabled a static IP address is used Possible Values b0 Disabled b1 Enabled Default Value b1 Unit Reset Required Hard 11 5...

Страница 31: ...gical Name HostInterface WLAN IPv4 DNS1 Description Defines the IP address of the 1st name server Possible Values Default Value 0 0 0 0 Unit Reset Required Hard 11 5 8 DNS2 Logical Name HostInterface...

Страница 32: ...arameter WIFI WPA2 is irrelevant Possible Values 0x00 EAP disabled 0x01 TLS 0x02 TTLS 0x03 FAST 0x04 PEAP Default Value 0x00 EAP disabled Unit Reset Required Hard 11 5 12 EAP Inner Method Logical Name...

Страница 33: ...ce WLAN Security EAP Enable_OKC Description Enables or disables opportunistic key caching OKC which decreases the time needed for authentication Possible Values b0 Disabled b1 Enabled Default Value b0...

Страница 34: ...ost Possible Values 0 65535 Default Value 0 Unit Reset Required Hard 11 6 Indicator Settings 11 6 1 Buzzer Signalization Logical Name DigitalIO Signaler Buzzer ActivationSources Description Defines th...

Страница 35: ...ssible Values b0 Switch off function disabled b1 Switch off function enabled Default Value b1 Unit Reset Required None 11 7 3 Right Button Power Off Logical Name DigitalIO Button Right Enable_PowerOff...

Страница 36: ...nment for the right button 0x00 The button has no function 0x01 Unlocks the scan function 0x04 Starts a new scan In Continuous Read Mode it also stops a scan 0x20 Toggles the trigger mode between Sing...

Страница 37: ...shes after successful reading of a barcode or an RFID tag The connection between the device and the host has timed out Check the connection The red LED lights up after trying to read a barcode or an R...

Страница 38: ...al cleaners lyes or similar 13 2 Contacts To clean the contacts use a clean and dry cleaning cloth Do not use chemical cleaners lyes or similar 13 3 Fingerless Glove and Battery The fingerless glove a...

Страница 39: ...sioning Decommissioning For prolonged decommissioning disconnect the scanner unit from the fingerless glove and slide the scanner unit out of the pocket Then remove the battery Make sure to store the...

Страница 40: ...isposal Disposal Never dispose of LiPo batteries in household waste LiPo batteries can be disposed of at special collection points Before disposal make sure that the LiPo battery is completely dischar...

Страница 41: ...any parts or equipment does not extend the period of warranty provided for herein THIS LIMITED WARRANTY IS THE MANUFACTURER S ONLY WARRANTY FEIG ELECTRONIC DOES NOT GIVE WARRANTIES OF MERCHANTABILITY...

Отзывы: