8
、
CLEANING AND MAINTENANCE
Disconnect the power plug before carrying out any adjustments or maintenance
8.1 Cleaning
Keep the ventilation slots of the machine clean to prevent overheating of the engine.
Regularly clean the machine housing with a soft cloth, preferably after each use.
Keep the ventilation slots free from dust and dirt.
If the dirt does not come off use a soft cloth moistened with soapy water.
Never use solvents such as petrol, alcohol, ammonia water, etc. These solvents may
damage the plastic parts.
8.2 Replacing carbon brushes
Remove and check the carbon brushes regularly.
Replace when they have worn down to the limit mark.
Keep the carbon brushes clean and free to slip in the holders.
If the carbon brushes need to be replaced, have this done by a qualified repair person
(always replace the two brushes at the same time)
Lubrication
All the bearings in this tool are lubricated with a sufficient amount of high grade lubricant for the life
of the unit under normal operating conditions,
therefore no further lubrication is required.
Suspected malfunctions are often due to causes that the users can fix themselves. Therefore
check the product using this section. In most cases the problem can be solved quickly.
8.3 Maintenance
Our machines have been designed to operate over a long period of time with a minimum of
maintenance. Continuous satisfactory operation depends upon proper machine care and regular
cleaning.
If the supply cable is damaged, it must be replaced by the manufacturer, its service agent or
similarly qualified persons in order to avoid a hazard.
9
、
TECHNICAL DATA
230-240V ~ 50Hz
Input power
710W
Chuck capacity
Max. Ø 13mm
No load speed
0-3000/min
10
、
NOISE AND VIBRATION
The declared vibration total value has been measured in accordance with a standard test method
and may be used for comparing one tool with another.
The declared vibration total value may also be used in a preliminary assessment of exposure.
The vibration emission during actual use of power tool can differ from the
declared total value depending on the ways in which the tool is used.
Voltage /
Frequency
07