Steam Gun
4. Operation
1: Place steam cleaner on a flat, level surface.
2: Open the safety cap. Use the measuring cup to fill water into the boiler. Close the boiler with the
safety cap.
3: See the below table to determine the amount of water you need to steam up.
No.
Name
Function
1
Steam nozzle Output of steam
2
Accessory
lock
Connected
with
accessories.
Remove the accessories when
pressed down
3
Adjust button
Adjust the steam amount
4
Steam lock
Steam off / Steam auto come out
5
Steam button Control the steam states
Amount of water
Duration of steam
500ml
Approximately 15 minutes
1000ml
Approximately 30 minutes
1500ml
Approximately 45 minutes
2000ml
Approximately 55 minutes