8. MAINTENANCE AND STORE
Safety is an obligation of the owner. Periodic inspection, adjustment and lubrication will keep your
generator in the safest and most efficient condition possible. In order to keep the engine in good
condition, you must check and maintain it regularly. Please follow the schedule below.
Maintenance Schedule
Regular Service Period
(
3
)
Each
use
First
month
or
10 hrs
Every 3
months or
50 hrs.
Every 6
months
or
100hrs
Every
2 years
or
300 hrs.
Item
Engine oil
Check level
⊙
Replace
⊙
⊙
⊙
Air cleaner
Check
⊙
Clean
⊙
(1)
Replace
⊙
Spark plug
Check & adjust
⊙
Replace
⊙
Spark arrester
Clean
⊙
⊙
⊙
Valve Clearance
Check & adjust
⊙
(2)
Fuel tank & filter
Clean
⊙
Cylinder Head
Clean
After every 300 hrs(2)
Fuel hose
Check
Every 2 years ( Replace if necessary)(2)
(1)
Maintenance more frequently when used in dusty or unusually wet areas.
(2)
These items should be serviced by your servicing dealer, unless you have the proper tools, data
and technical skills.
●
If you often work at high temperature or high load, you should replace the engine oil every 10
hours.
● If you work in dusty or harsh environments, clean the filter element of the air filter every 10 hours.
If necessary, air filter elements should be replaced every 25 hours.
● The inspection period and time should be maintained on a first-come basis.
● If the maintenance cycle has passed, the maintenance should be carried out as soon as possible
according to the above table.
■ Stop the engine before starting maintenance work. The engine should be placed horizontally. To
prevent the engine from starting, separate the spark plug cap from the spark plug.
■ Never operate the engine in a closed area or it may cause unconsciousness and death within a
short time. Operate the engine in a well ventilated area.
8.1 Engine Oil Replacement
When the engine shut down, the oil should be removed quickly and completely.
1).Loosen the air filter maintenance cover screw and remove the air filter maintenance cover.
2).Take out the dipstick
3).Drain dirty oil.
Содержание FG2000i-B
Страница 6: ...2 SAFETY WARNING LABEL Safety warning label Guaranteed sound power level...
Страница 7: ...3 COMPONENTS IDENTIFICATION 3 1 Components Feature...
Страница 23: ...10 TROUBLESHOOTING...
Страница 24: ...11 ELECTRICAL DIAGRAMS...
Страница 27: ...BUILDER SAS 32 rue Aristide Berg s ZI 31270 Cugnaux France MADE IN PRC 2023...