Step 1 - Install Drivers
Step 1A – Connect Source Power to Driver
IMPORTANT SAFETY NOTE: TO REDUCE RISK OF ELECTRICAL SHOCK, TURN OFF AC CIRCUIT BREAKER PRIOR TO COMMENCING ANY ELECTRICAL WORK AND
CONNECTING DRIVER(S) TO AC POWER SOURCE. VERIFY THAT LIVE POWER IS NOT PRESENT AT JUNCTION BOX WHEN MAKING CONNECTIONS.
Determine loca on of driver.
Note: It is best to locate the drivers as close as
possible to the ligh
ࢼ
ng to reduce the possibility
of voltage drop occuring. If possible, the driver
should be within 15 feet of the post that will
accept the 20' starter cable.
Route exterior rated wiring from compa ble
dimmer switch/AC power source to loca on of
driver.
Connect drivers to dimmer switch/AC power
source.
Connect 20' starter cable and route from driver
to post using supplied wire nuts.
1.
Power (by customer)
2.
Light Switch (by customer)
1
3.
24v Dimmable Driver
2
4.
LED Starter Cable (20')
5.
LED Connector Pair (Female
Connector)
6.
LED Light Strip
LIGHTING COMPONENTS:
1. Mount ver cally only. See Switch Compatabilty
Spec Sheet at www.feeneyinc.com
2. See Driver Spec Sheet at www.feeneyinc.com
3
4
1
2
5
6
TOP RAIL LIGHTING - WIRING DIAGRAM
BOTTOM RAIL LIGHTING - WIRING DIAGRAM
3
4
1
2
5
6
Note: If using both top and bo
om rail ligh
ࢼ
ng, run each with their own starter
cable a
ached to the driver.
Alterna
ࢼ
vely, a separate driver may be supplied for top and bo
om rail ligh
ࢼ
ng,
allowing for independent control of each circuit.
TOP & BOTTOM RAIL LIGHTING - WIRING DIAGRAM
3
4
1
2
5
6
5
6
4
1
2
3
4
5
6