SELECT A MrSteam CU SERIES GENERATOR
The resultant calculated volume of the steam room determines
the Model CU steambath generator required. Steam room size
and additional constructional factors affect model selected.
A.
To determine the steam room volume first multiply
Length x Width x Height of the steam room
___________________________________________________________________
Example: A steam room 8' x 9' x 8' = 576 cu. ft. (volume).
Select the MrSteam Model which is the next larger volume.
In this example, Model CU750 is the correct selection.
Example: 2 Steam rooms each 6' x 10' x 7' x 2 rooms = 840 cu.
ft. (volume). In this example, Model CU1000 is the correct
selection.
Insure adequate consideration is given to assure
that the CU unit selected is not undersized for the room.
Add 1 cu. ft. to the steam room volume for every 1 ft. above
the 25 ft. pipeline from the generator to steam room. For more
information please contact MrSteam at 1-800-76 STEAM
B.
The selection guidelines are recommendations
only. Always consult with contractor, designer or architect. For
general information, contact East Coast: 1-800-767-8326 or
West Coast: 1-800-727-8326.
Model
Max Room Water Inlet Generator Outlet
Dimensions
(inches)
Shipping
No.
KW Volume*
(cu ft)
Size NPT
Size, NPT
W
L
H
Wt.
(lbs.)
CU360
9
400
1/4"
1"
20
30
38
230
CU500
12
500
1/4"
1"
20
30
38
230
CU750
18
750
1/4"
1"
20
30
38
230
CU1000
24
1000
1/4"
1"
20
30
38
230
CU1250
30
1250
1/4"
1"
20
30
38
230
CU1400
36
1400
1/4"
1"
20
30
38
230
CU2000
48
2000
1/2"
1"
24
33
44
330
CU2500
60
2500
1/2"
1"
24
33
44
380
CU3000
72
3000
1/2"
1"
24
33
44
390
CU4500 108
4500
1/2"
1-1/2"
28
34
59
625
C.
When specifying a CU Commercial
Steambath generator the following is strongly
recommended for best performance and user
satisfaction.
1. One CU steambath generator should service no
more that two (2) steam rooms, each relatively
similar in size and construction.
2. If two (2) steam rooms are serviced by one (1) CU
generator, the combined resultant room volume
of the two rooms should not exceed 1400 cu.ft.
3. Each room must Be operated with the appropri-
ate Digital 1 temperature control system inclusive
of the room operating temperature control and
the high-limit temperature control.
4. In any case, the purchaser and/or owner/operator
must consult with a designer, architect, and/or
consultant to assure the proper specification of
the steam generator.
*After taking into consideration all factors affecting resultant steam room volume including length,
width & height of steam room and distance to generator, select proper Model CU generator.
Consult with an architect, engineer, designer and/or contractor before making final selection.
SPECIFICATION CHART