mr
.
steam
®
C U S E R I E S
Installation, Operating & Maintenance Manual
.
Install
steambath
generator
on
a
solid
and
level
surface,
and
mechanically
secure
generator
in
place.
.
Provide
access
to
the
steambath
generator
for
servicing.
See
page
7-9
for
Dimensional
&
Clearance
Specifications
8.
Steam
line,
safety
valve
and
drain
valve
and
plumbing,
and
steamheads
become
hot
during
operation
and
remain
hot
after
shutdown
for
a
period
of
time.
Provide
appropriate
protec-
tion,
including
insulating
plumbing
lines.
Avoid
plumbing
runs
and
steam
head
locations
that
can
come
in
contact
with
service
personnel
and
bathers.
See
figure
1.
away from the bather seating areas and traffic pat-
terns as required to prevent incidental contact with
the steamhead or direct steam emission.
A
LOCKED
UTILITY
ROOM
THAT
ONLY
PERMITS
ACCESS
TO
THE
STEAM
GENERATOR
AND
ITS
CONTROLS
BY
AUTHORIZED
PERSONNEL
AND
IS
NOT
ACCESSIBLE
TO
THE
GENERAL
PUBLIC
IS
STRONGLY
RECOMMENDED.
(1-4):
.
MrSteam
®
CU
commercial
steambath
generators
are
designed
to
NEMA
Type
1
requirements
and
are
intend-
ed
for
indoor
use
only.
They
are
to
be
located
indoors
in
a
dry,
clean
location
and
are
not
to
be
subjected
to
mois-
ture,
condensate,
hose
wash
down
or
the
like.
2.
Do
NOTinstall
steambath
generator
outdoors
or
wherev-
er
environmental
conditions
may
effect
the
safety
and/or
performance
of
the
generator.
.
Do
NOT
install
steambath
generator
in
locations
such
as
unheated
attics
or
basements,
or
where
water
could
freeze.
.
Do
NOT
install
steambath
generator
near
flammable
or
corrosive
materials,
or
chemicals
such
as
gasoline,
paint
thinners,
or
the
like.
Installation
in
areas
having
high
concentrations
of
chlorine
(such
as
pool
equipment
room)
must
be
avoided.
.
Select
a
location
for
steam
generator
in
accordance with items 1-4 above and within 25 feet of
the steam room. Reference “Dimensional & Clearance
Specifications” information on pg. 7-9. See page 6 for
guidance if generator is more than 25 feet from steam
room, add 1 cu. ft. to the total volume size for every 1 ft.
above the 25 ft. pipeline of the steam room when sizing
the steam generator.
U T I L I T Y R O O M
3
⁄
4
" Steam
Solenoid
3
⁄
4
" Steamhead
with Acrylic Shield
Steam
Generator
Fully
Insulated
Steam Pipe
Digital 1
Sensor
1" Steam
Outlet
S T E A M R O O M
e
M
FOR ILLUSTRATIVE PURPOSES ONLY.
Optional equipment shown. Consult with qualified designer,
architect or contractor for steam room construction details, including location of steam head(s) and sensors.
FOR ILLUSTRATIVE PURPOSES ONLY
TYPICAL INSTALLATION
Figure 1:
LOCATING THE STEAM GENERATOR UNIT
9. Each steamhead must be located
5