- 6 -
Electrical Information
PERMANENTLY CONNECTED
MODEL
VOLTAGE
TOTAL AMPS
MAX FUSE SIZE
VOLTAGE
MAX FUSE SIZE
SSRSP5052
230/60/1
9.5
15
120/60/1
15
SSRSP5952
230/60/1
14.5
20
120/60/1
15
SSRSP7752
230/60/1
14.5
20
120/60/1
15
MODEL
VOLTAGE
TOTAL AMPS
CORD STYLE
SSRSP5052
230/60/1
9.5
15AMP NEMA 6-15
SSRSP5952
230/60/1
14.5
20AMP NEMA 6-20
SSRSP7752
230/60/1
14.5
20AMP NEMA 6-20
SELF CONTAINED
REMOTE
SELF CONTAINED
CORD CONNECTED OPTIONAL
(E3091-2 EXCEL)
INSTALLATION INSTRUCTIONS
Locating Display Case
The case should be located where it is not subjected to the direct rays of the sun, heating ducts, grills,
radiators, or ceiling fans, nor should it be located near open doors or main door entrances. Also, avoid
locations with excessive air movement or air disturbances.
The case requires a minimum of 12” clearance at the rear of the unit for air discharge. Do not locate case
with back tight against the wall.
No clearance is needed on sides of the unit.
Removing Case From Shipping Skid and General Installation
CAUTION:
Do not push or pull against the top end glass, or
door frames, and do not pull on end panels when removing the case
from the skid or moving the case. Case damage or glass breakage will result.
1.
Remove crate top and sides and note missing or damaged items as explained in the pre-installation
procedures outlined above.
2.
Move the case as near as possible to the final location before removing it from the shipping skid.
3.
Remove the (4) brackets that secure the case to the shipping skid.
4.
Prepare cabinet according to instructions in this section that pertain to your model.
5.
Lift the case off of skid and into required position. Only lift the case from under the rear lip and front
bottom trim channel above the base. Note: Do not push or pull on front bottom trim channel.
6.
The case must be level for proper drainage of defrost condensate to the condensate evaporator. Using
the wrench provided, level and square the case as needed by adjusting the leg leveler in each corner of
base. The 6’cases also have a set of leg levelers in the center which must be adjusted so the base is flat.
7.
The leveled case must be sealed to the floor using a NSF Listed Sealant.
Cleaning
For initial setup, clean the case as outlined in the “Weekly Cleaning” section of this manual.