Error codes
It is possible for error codes to be displayed on the control screen. In the event of a malfunction an alarm
will sound and the alarm indicator
will be displayed on the display. An error code or codes will flash
intermittently on the display. If there are multiple codes, the display will continuously cycle through
them. The following photo shows error code “E0” as an example.
Mute: You may mute the alarm by pressing and releasing the wrench button. The red ringing bell and all
error codes will still be displayed. When the fault is remedied the control will return to normal operation
and will automatically clear the codes from the display.
Carel Control
EO = Air sensing probe - Open or shorted
E1 = Evap. coil probe - Open or shorted
TEMPERATURE PROBE COMMON RESISTANCE CHART
Probe Temp
Maximum
Resistance [
Ω]
Normal
Resistance [Ω]
Minimum
Resistance [
Ω]
32°F(0°C)
27.83
27.28
26.74
77°F(25°C)
10.1
10
9.9
212°F(100°C)
1
0.97
0.94
Refrigerated Self-Serve Merchandiser (High Profile)
Page 10