CONDITION
Case Is Not Holding Temperature
Refrigerated merchandisers are not intended as storage
refrigerators and will not “pull down” room temperature
products efficiently.
LOAD CASE INTERIOR WITH PRE-
CHILLED 38°F OR COLDER PRODUCT ONLY
Refrigerated Merchandisers
are subject to air disturbance and due to
direct sunlight and close proximity of heating ducts, grills, radiators,
ceiling fans or main doors. Also, avoid locations where the unit is
subject to high humidity such as
near cases with water misting or fogging devices.
Check Ambient Conditions of the Location
Most of our cases require a maximum ambient of 75°F / 55% RH
(Relative Humidity) Exceeding either or both can result in temperature
issues as the evaporator coil ices up and restricts airflow.
Check that the condenser air inlet and outlet are not restricted.
If equipped, check condenser coil filter is clean.
Check that the condenser coil is clean
Non-refrigerated
cases do not regulate internal temperature and may
be slightly higher than ambient temperature due to the lighting in the
unit or
direct sunlight.
Mechanical Thermostat (if
equipped)
If equipped, is a coil sensing thermostat that also controls the cut-in as
well as the cut-out so that the evaporator coil does not ice up.
Check that thermostat is turned on.
Adjust thermostat accordingly, the coldest setting is 9.
Electronic Unit Controller (if
equipped)
Check that the control is turned on.
TEMPERATURE ISSUES
CD or CRR/RSS REFRIGERATED TOP UNIT
OPEN AIR / CLOSED DOOR MERCHANDISERS
STAND ALONE RSS & HYBRID
9