7
Installation and Maintenance Instructions
Model WV450XL Series
• M20 entries standard
• Body color natural black
• IP66 rated
• Zone 1 rated, IECEx, ATEX, Ex d IIB +H2 T6 Gb, Ex de IIB +H2
T6 Gb
Certification
Certificate Nos.: ATEX Cert No.: UL DEMKO 06 ATEX04259693X
IECEx Cert No.: IECEx UL 06.0010X
ATEX coding:
II 2
Protection:
Ex d IIB+H2 T6 Gb [-55°C ≤Ta≤ 55°C]
Ex de IIB+H2 T6 Gb [-20°C ≤Ta≤ 55°C]
Standards:
EN60079-0: 2012, EN60079-1: 2007, EN60079-7: 2007.
IEC60079-0: 5
th
Ed., IEC 60079-1 6
th
Ed., IEC 60079-7:
4
th
Ed.
Special Conditions for Safe Use:
1) Potential electric static charging hazard. Use only a water
dampened cloth when cleaning the exterior of the unit.
2) The capacitance value of unearthed metal parts is 10 pF, when
measured per IEC/EN 60079-0.
3) Contact the manufacturer for information on the dimension of the
flameproof joints.
Condições especiais para o uso seguro:
1) Perigo de potencial carga eletroestática. Ao limpar a parte
externa da unidade, utilize apenas um pano úmido.
2) O valor de capacitância de peças metálicas desenterradas é
10 pF, quando medido por IEC / EN 60079-0.
3) Contate o fabricante para obter informação sobre a dimensão
das juntas à prova de fogo.