10

  

  

Installation and Maintenance Instructions

Model WV450XL Series

•  Certifique-se de utilizar apenas as juntas componentes 

certificadas corretas e de que o equipamento instalado esteja 

blindado e devidamente conectado à terra. As entradas das juntas 

são de M20-1,5 6 H. Os cabos de alimentação são certificados 

para temperatura mínima de 85 °C.

•  Ensure there is not too much slack of cable cores within the unit, 

due to space limitations. 

•  Ensure that only the supplied stopping plugs are used to blank 

off unused gland entry points. Failure to do so may negate the IP 

rating on the unit.

•  In all countries, the wiring must comply with all national and 

local codes and standards.

•  Ensure that all nuts, bolts and fixings are secure.

Wiring the WV450XLD Flameproof Models

SHOCK HAZARD—To avoid electrical shock hazards, do not 

connect wires when power is applied.

This section has wiring instructions for the two flameproof models: 
•  WV450XLD 24 Vdc
•  WV450XLD 110-220 Vac
The maximum wire gauge is 2.5 mm

2

 (12 AWG). The wire must be 

rated 85 °C or higher.

 

Use only stranded or multiple strand cable to 

terminate the beacon.
Cable termination for these models should be in accordance with 

specifications applying to the application. It is recommended that all 

cables and cores should be fully identified. Use the appropriate cable 

gland for the application. Gland entry threads are M20-1.5 x 6H.

Содержание WV450XL Series

Страница 1: ...25500104A Rev A0 1113 Printed in U S A Model WV450XL Series GRP LED Beacon for Use in Hazardous and Marine Locations Installation and Maintenance Instructions magenta and yellow not shown ...

Страница 2: ...ns and controllers manufactured by Federal Warning Systems are warranteed for two years on parts and one year on labor No agent employee representative or distributor of Seller has any authority to bind the Seller to any representation affirmation or warranty concerning the goods and any such representation affirmation or warranty shall not be deemed to have become a part of the basics of the sale...

Страница 3: ...Flameproof Models 10 Wiring the 24 Vdc Model WV450XLD 11 Wiring the 110 220 Vac Model WV450XLD 12 Wiring the WV450XLE Increased Safety Models 13 Wiring the 24 Vdc Model WV450XLE 15 Wiring the 110 220 Vac Model WV450XLE 16 Changing the Flash Pattern 16 Safety Messages to Maintenance Personnel 19 Maintaining the Beacon 20 Cleaning the Enclosure 20 Replacing the LED Array 21 Ordering Accessories and ...

Страница 4: ...nt parts 23 Figures Figure 1 Mounting hole locations Ex d version 8 Figure 2 Mounting hole locations Ex de version 9 Figure 3 Connections for 24 Vdc model 11 Figure 4 Connections for for 110 220 Vac model 13 Figure 5 Terminal block for Model 450XLE 14 Figure 6 Connections Ex de DC or AC beacons 15 Figure 7 Location of DIP switch for flash patterns 18 ...

Страница 5: ...ructions and precautions you should follow Read and understand all instructions before installing or operating this equipment The circuitry of the beacon can be damaged by an electrostatic discharge Follow antistatic procedures while installing the beacon Never alter the unit in any manner Safety in hazardous locations may be endangered if additional openings or other alterations are made in units...

Страница 6: ...weight as compared to traditional metal housings The GRP construction also saves time and money over the life of the product by reducing or in most cases completely eliminating the need to perform regular field inspections of the flame path The WV450XL Series comes standard with metric entries a 316 stainless steel dome guard and an extended life LED emitter The flameproof D versions come standard...

Страница 7: ...60079 7 4th Ed Special Conditions for Safe Use 1 Potential electric static charging hazard Use only a water dampened cloth when cleaning the exterior of the unit 2 The capacitance value of unearthed metal parts is 10 pF when measured per IEC EN 60079 0 3 Contact the manufacturer for information on the dimension of the flameproof joints Condições especiais para o uso seguro 1 Perigo de potencial ca...

Страница 8: ...abels and tags before removing or discarding them Disposal of all shipping materials must be carried out in accordance with national and local codes and standards If any parts are missing please call Federal Signal Customer Support at 1 708 534 4756 or 1 877 289 3246 Mounting the Beacon SECURE TO FLOOR OR WALL To prevent injury this apparatus must be securely attached to the floor or wall in accor...

Страница 9: ...essages for Wiring When installing and operating explosion proof electrical equipment the relevant national regulations for installation and operation e g EN60079 14 and IEC Wiring Regulations must be observed To maintain the explosion proof integrity of the enclosure DO NOT damage the dome or threads while disassembling or reassembling unit Painting and surface finishes other than those applied b...

Страница 10: ... all countries the wiring must comply with all national and local codes and standards Ensure that all nuts bolts and fixings are secure Wiring the WV450XLD Flameproof Models SHOCK HAZARD To avoid electrical shock hazards do not connect wires when power is applied This section has wiring instructions for the two flameproof models WV450XLD 24 Vdc WV450XLD 110 220 Vac The maximum wire gauge is 2 5 mm...

Страница 11: ... Wiring the 24 Vdc Model WV450XLD To wire the beacon 1 Use the hexagon key to unscrew the grub screw on the dome cover assembly one full turn 2 Remove the cover from the housing by turning the cover counter clockwise If the dome cover assembly will not unscrew back out the grub screw a few additional turns 3 Slide out the PCB until the terminals clear the case Strip the wire insulation 5 mm to 6 m...

Страница 12: ... Ensure that the unused wire entry is sealed with the provided brass M20 1 5 x 6 g stopping plug component certified Wiring the 110 220 Vac Model WV450XLD To wire the beacon 1 Use the hexagon key to unscrew the grub screw on the dome cover assembly one full turn 2 Remove the cover from the housing by turning the cover counter clockwise If the dome cover assembly will not unscrew back out the grub ...

Страница 13: ...ould be a maximum gap of 0 3 mm 0 012 in between the faces of the enclosure and cover Turn the grub screw one full turn or until the screw contacts the housing 10 Ensure that the unused wire entries are sealed with the provided brass M20 1 5 x 6 g stopping plug component certified Wiring the WV450XLE Increased Safety Models SHOCK HAZARD To avoid electrical shock hazards do not connect wires when p...

Страница 14: ...nals shall be insulated for the appropriate voltage and this insulation shall extend to within 1 mm of the metal of the terminal throat The WV450XLE terminal block is supplied with three poles and two conductors per pole The terminal block allows for easy supply in and loop out wiring to connect beacons in series See Figure 5 The terminal block uses a spring clamp connection to engage the wire To ...

Страница 15: ... either side of any terminal must be joined in a suitable manner e g two conductors into a single insulated crimped bootlace ferrule 3 See Figure 5 on page 14 Connect the positive power source wire to the terminal block pole marked L1 4 Connect the negative power source wire to the terminal block pole marked N1 5 Secure the cover on the terminal box with the four M4 screws Ensure that the gasket i...

Страница 16: ...ck pole marked N1 5 Connect the ground wire to the terminal block pole marked with the ground symbol 6 Secure the cover on the terminal box with the four M4 screws Ensure the gasket is properly seated to maintain the IP rating Do not overtighten the cover screws Changing the Flash Pattern LIGHT HAZARD To be an effective warning device the beacon produces bright light that can be hazardous to your ...

Страница 17: ...m the housing by pulling up on the base of the LED array not the LEDs 5 See Figure 7 and Table 1 on page 18 Select a flash pattern by setting the DIP switches on SW1 Strobe Simulation 60 FPM is the default 6 Insert the PCB into the enclosure with the terminal block wires facing the largest side of the PCB offset inside the enclosure Ensure that the bottom edge of PCB is trapped between the holding...

Страница 18: ... patterns LOCATION OF DIP SWITCH FOR FLASH PATTERNS DEFAULT POSITION FOR STROBE SIMULATION 60 FPM Table 1 SW1 settings for flash patterns Rotate 120 RPM Variable Pulse Strobe Simulation 60 FPM Strobe Simulation 90 FPM Severe Alert Steady On Blink 60 FPM Random Blink Description ON ON ON ON ON ON ON ON 1 2 3 ...

Страница 19: ...enance to the beacon system must be done with power turned off Any maintenance to the beacon system must be performed by a trained electrician who is thoroughly familiar with all applicable national and local codes in the country of use Never alter the unit in any manner Safety of the unit may be affected if additional openings or other alterations are made to the internal components or housing Th...

Страница 20: ... charge buildup AVISO DE PERIGO PERIGO DE POTENCIAL CARGA ELETROESTÁTICA Em caso de ter que limpar a unidade limpe APENAS a parte externa com um pano úmido a fim de evitar o acúmulo de carga eletroestática During the working life of the beacon it should require little or no maintenance GRP glass reinforced polyester will resist attack by most acids alkalis and chemicals and is as resistant to conc...

Страница 21: ...ght may occur BURN HAZARD The LED emitter gets hot enough to burn you Always allow the emitter to cool before handling it STATIC SENSITIVE DEVICE The circuitry of the beacon can be damaged by an electrostatic discharge ESD Always follow anti static procedures while handling the PCB Tools needed 2 0 mm A F hexagon key No 2 Phillips screwdriver To replace the LED array 1 Remove the PCB a Disconnect ...

Страница 22: ...ole in the bracket d Secure the bracket in place by re installing the two 8 32 pan head screws through the LED array and into the bracket e Reconnect the two leads from the LED array to the PCB J2 and SPADE connections 4 Insert the PCB into and test the beacon a Insert the PCB into the enclosure with the terminal block wires facing the largest side of the PCB offset inside the enclosure Ensure tha...

Страница 23: ...ed to Federal Signal for service To order accessories and replacement parts call Federal Signal Customer Support at 708 534 4756 or 877 289 3246 Table 2 Replacement parts Description Part Number Cover Dome Assy Amber K859500582 Cover Dome Assy Blue K859500582 01 Cover Dome Assy Clear K859500582 02 Cover Dome Assy Green K859500582 03 Cover Dome Assy Magenta K859500582 04 Cover Dome Assy Red K859500...

Страница 24: ...24 Installation and Maintenance Instructions Model WV450XL Series ...