background image

Page 5

 Section IV Cont.

   MODEL 183K

STANDARD & OPTIONAL FEATURES

1. The system consists of a Model UM183K controller,

    a UM80K amplifier and a UCO30-4 cable, ( 4 foot

    version), or a UCO30-15, ( 15 foot version).

2. The UM183K controller can control the siren and

    warning lights.

3. A 60 amp progressive slide switch supplies 20 amps

    of power per switch position.

4. Horn Ring Transfer

a. Horn and Horn Ring connections on the rear

    of a unit MUST be made to permit operation

    of Manual siren and Yelp of Hetro Override.

See siren & warning light control for correct hook

up of the Horn Ring circuit.

5. Indicator lights to alert the user that there is an active

    circuit at a glance.

Optional Equipment can include:

1. UPA2

a. UCAR-183K, P.A. cable

b. UMNCT-SB, P.A. microphone

2. UDMK, Dual Mode

SIREN & WARNING LIGHT CONTROL

The progressive slide switch position 1, 2, & 3

turn on warning lights. Position 3 turns on the

siren and horn ring controls.

The toggle switch controls the siren’s mode of

operation during slide switch position 3.

OFF - No Siren.

MAN - Allows the siren to operate in manual mode.

AUTO - Siren & override functions automatically.

REAR CONNECTIONS

1. B1 terminals from left to right are:

a. Grd - Battery Ground

b. SPK - Siren Driver.

c. SPK - Siren Driver.

d. HORN - Spliced into the car horn circuit.

e. Ring - Spliced into the car horn circuit.

2. B2 terminals from left to right are:

a. +12V - Battery positive.

b. 1-2-3 - Slide switch output during position

     1, 2, & 3.

c. 2-3 - Slide switch output only during switch

    positions 2 & 3.

d. 3 - Slide switch output during position 3 only.

e. 1- Slide switch output during position 1 only.

HORN RING CONNECTIONS

1. Cut wire apart between either the Horn Ring and the

    Horn Relay or between the Horn Relay and the vehicle

    Horn. Extend the wires to reach the rear of the control

    unit.

2. Connect the wires to the B1 terminals screws marked

     HORN and RING.

DO NOT REVERSE THE WIRES.

Содержание Unitrol 280 Series

Страница 1: ...AN 80K REV 14 FEB 03 80K AMPLIFIER Sirens Sirens with P A Sirens with P A and Switching INSTALLATION OPERATION FS UNITROL 1108 RAYMOND WAY ANAHEIM CA 92801 714 871 3336 Fax 714 871 3418 WWW UNITROL CO...

Страница 2: ...ions Section VIII pg 9 P A Kit Installation Section IV pg 4 Model183K Standard Optional Features Section IV pg 5 Siren Warning Light Control Section IV pg 5 Rear Connections Section IV pg 5 Horn Ring...

Страница 3: ...W OUTPROOFTRANSISTORPROTECTION 1 Output transistors blown out in normal sirens by failures of the siren speaker or its wiring are protected in the Unitrol 80K by automatic circuitry a Short circuited...

Страница 4: ...hing Kawasaki wire colors with amplifier harness wires AIRHORN 1 12V applied to the amplifier s AIR HORN wire 3 pin power connector operates the air horn 12V can be supplied by a separate switch or th...

Страница 5: ...o match horn button polarity Connect other side of switch to terminal 9 OptionalConnectionsorEquipmentcaninclude a AIR HORN See item 3 below b Microphone radio P A See Section V c Intrusion Alarm See...

Страница 6: ...de by pressing the microphone button and talking Siren sounds are stopped until mic button is released INSTALLATION 1 Locate area for jack installation Allow 1 diameter clearance space for back portio...

Страница 7: ...ition 1 2 3 turn on warning lights Position 3 turns on the siren and horn ring controls The toggle switch controls the siren s mode of operation during slide switch position 3 OFF No Siren MAN Allows...

Страница 8: ...ontrols siren as follows During MAN Siren rises and falls only as horn ring is manually pressed and released During WAIL Horn ring activates 5 second Yelp During HI LO Horn ring activates 5 second Het...

Страница 9: ...ntain blades audio connections will be established when radio cable is plugged into radio head 2 Radio Control If radio power control is desired locate the radio s transmit and receive control wires a...

Страница 10: ...for warning lights SUGGESTEDCONNECTIONS 1 Since there are no uniform lighting arrangements there are no set rules for connecting wires Instructions appearing below are only suggestions You may prefer...

Страница 11: ...is undesirable the positive output may be used to operate siren sounds or the air horn Page 9 c Connect one terminal either one of system on off switch to desired pin in amplifier 12 pin connector see...

Страница 12: ...switch on bottom of amplifier chassis to match power rating of speakers to be used 3 Install amplifiers with 4 inches maximum between cabinets PRELIMINARYCONNECTIONS 1 Interconnect AIR HORN wires fro...

Страница 13: ...g 2 Set slide switch on bottom of amplifier chassis to match power rating of speakers to be used 3 Install amplifier with 4 inches maximum between cabinets Page 11 PRELIMINARYCONNECTIONS 1 Interconnec...

Страница 14: ...watts by vehicle voltage 13 volts nominal The result will be amperes 5 Motors Relays Most motors used in warning light bars draw 1 ampere or less Most relays draw 3 amperes or less 6 Keep in mind that...

Страница 15: ...r on which unauthorized repairs or modifications have been made nor does it cover units that have been abused or used beyond limits stated in specifications FIVE YEARWARRANTY LIMITATIONS TECHNICAL SUP...

Страница 16: ...longer exposures to moderately loud sounds For hearing conservation guidance refer to Federal State or local recommendations OSHA Standard 1910 95 offers guidance on Permissible Noise Exposure All ef...

Страница 17: ...age rating In order for the electronic siren to function properly the ground connection must be made to a solid chassis component and not to an insulated point Page 15 Sound output will be severely re...

Отзывы: