![Federal Signal Corporation SpectraLux SIFZ Front ILS Скачать руководство пользователя страница 13](http://html1.mh-extra.com/html/federal-signal-corporation/spectralux-sifz-front-ils/spectralux-sifz-front-ils_installation-maintenance-and-service-manual_3846909013.webp)
13
Installation, Maintenance, and Service Manual
Federal Signal
www.fedsig.com
Programming the Discrete-Wire SIFZ ILS
Programming the Discrete-Wire SIFZ ILS
The white programming wire enables you to program the functions of the control wires. A
description of each function is listed in Table 4. Only one control wire can be modified at a
time. If more than one control wire is active, the programming wire is disabled.
To modify the function of a control wire:
1.
Connect the black wire from the light bar to ground (–GND), then apply 12 Vdc
(+BAT) to the 16 AWG red wire and the wire you want to modify.
2.
Cycle through functions by tapping the white programming wire from the light bar
to 12 Vdc (+BAT).
3.
To save the setting, let the function run for five seconds before removing power.
The available programming functions are listed in Table 4.
Table 4
Discrete-Wire SIFZ light bar controls
Light Bar Programming Wire Color
Programming Functions
Mode 1 Flash
Orange
28 flash patterns, 4 cruise patterns, Mode 2 Flash
overrides Mode 1.
Mode 2 Flash
Yellow
28 flash patterns (dimming disabled)
Takedowns
Black
Takedown location (Inner/Outer/Double)
White Flashing
(independent)
Light Blue
17 takedown patterns (Pattern 1 adds white to any
mode-wire flash pattern.) The rest of the patterns
flash the takedown lights independently.
Dimming
Light Brown N/A
Steady Burn Red
Red/White
Steady Burn Red location, 4 cruise patterns
Scene Light
Light Green Scene light location (Inner/Outer/Full)
Programming
White
Hold the wire to 12 Vdc (+BAT) more than five
seconds to reset all settings to the factory defaults
and also perform an LED scan.
Testing the Serial SIFZ ILS Controls
LIGHT HAZARD: To be an effective warning device, an emergency warning
system produces bright light that can be hazardous to your eyesight when
viewed at a close range. Do not stare directly into this lighting product at a
close range, or permanent damage to your eyesight may occur.
NOTE:
After the installation, check the entire system to ensure that the lights are flashing
properly and all light systems are operating properly.
To test the light bar controls:
1.
Connect the 16 AWG black lead from the light bar to the ground (–NEG) terminal of
the vehicle battery and the 16 AWG red lead to the positive terminal.
2.
Connect the black and black/white wires from the Serial Interface Module to the
ground (–NEG) terminal of the vehicle battery