![Federal Signal Corporation SpectraLux SIFZ Front ILS Скачать руководство пользователя страница 11](http://html1.mh-extra.com/html/federal-signal-corporation/spectralux-sifz-front-ils/spectralux-sifz-front-ils_installation-maintenance-and-service-manual_3846909011.webp)
11
Installation, Maintenance, and Service Manual
Federal Signal
www.fedsig.com
Control Wires for the Serial Interface Module
Table 2
SIFZ light bar controls and wires from the Serial Interface Module
Light Bar Control
Wire Color
Description of Function
Mode 1
Blue
Lowest priority
Mode 2
Blue/White
Overrides Mode 1
Mode 3
Black/Red
Overrides Modes 1 and 2
Steady Burn
Red/White
One (driver side) or two heads (driver and passenger
side) burn steadily when 12 Vdc is applied to
the control wire for Steady Burn. See “Selecting
Configuration Options for the “Selecting Configuration
Options for the Serially-Controlled SIFZ” on page
9.
Front Cutoff*
Green/White
Turns OFF power to the Split Front ILS
Front Enable*
Turns ON power to the Split Front ILS
Rear Cutoff
Orange/Black
N/A
Rear Enable
N/A
Intersection (SW-2 Switch
3 in theSerial Interface
Module is in the UP
position)
Scene Light, Left (SW-
2 Switch 3 in the Serial
Interface Module is in the
DOWN position)
Blue/Black
Typically a high activity pattern. Overrides all three
priority modes. Scene Light, Left is unavailable.
Applying 12 Vdc to the Scene Light, Left wire turns on
the left half of the light bar. Intersection is unavailable.
Flash Takedown
Red/Black
Flashes the Takedown lights in Modes 1, 2, and 3
with every flash pattern. To have the Takedown lights
remain off and flash only when the Flash Takedown
wire is activated, see “Selecting Configuration Options
for the Serially-Controlled SIFZ” on page 9.
Left Alley
Green/Black
N/A
Right Alley
Orange/Red
N/A
Takedown
White/Black
Provides white light to the front. Overrides Flash
Takedown lights and Front Cutoff.
Low Power
White/Black/Red
Dims the lights approximately 50 percent to prevent
blinding approaching drivers. Low Power is only
available in Modes 1 and 2 and is disabled when
switched to another flash pattern, including Mode 3
and Intersection.
Test Pattern (SW-2 Switch
3 in the Serial Interface
Module is in the UP
position)
Scene Light, Right (SW-
2 Switch 3 in the Serial
Interface Module is in the
DOWN position) Black/
White/Red
Black/White/Red
Cycles through each available color. Scene Light,
Right is unavailable.
Applying 12 Vdc to the Scene Light, Right wire turns
on the right half of the light bar. Light Bar Test Pattern
is unavailable.
*To set these options in the Serial Interface Module, see instruction sheet 2562248.