Chapter 3: Connecting the PA300-CN System
23
PA300-CN Siren Amplifier
Connections for the Park Input Circuit (Cable Assembly P/N 1461907)
The
Park Input
circuit sends a signal to the siren amplifier/relay module to mute all siren functions
except
Air Horn
and
Manual
when the vehicle transmission is shifted into park or neutral. The
Siren
Mute
option is configured with the Convergence Network Configuration Software.
To wire the
Park Input
option:
1
. By default, the park-input circuit is set through a jumper in the siren amplifier to be activated by a
GND signal. To change the circuit to +12 V activation, move the PARK INPUT jumper (J8) to the
position (– RING) shown in Figure 3.9.
Figure 3.9 Jumper setting for GND activation of PARK INPUT circuit
290A6790
−
+
J7
J9
J8
PARK
INPUT
GND DEFAULT
SETTING IS WHITE
ON PIN BASE.
JUMPER SETTING
FOR +12 V ACTIVATION
OF CIRCUIT
2.
Connect the gray PARK wire from the siren to the electrical circuit that pr12 V or –GND
when the vehicle transmission is in park (Figure 3.10) on page 24. Extend wiring with an 18 AWG
lead or thicker.
3.
Insulate spliced leads with butt-spliced wire connectors. Fold and seal unused leads. Use wire ties
and hold-downs for strain relief.