Figure 4.

A.

Slide Switch.

1.

LEFT (Position 1).

In this position, the light produces a left arrow

flashing pattern, instructing traffic to move left.

2.

CENTER OUT (Position 2).

In this position, a center out flashing pattern is

produced, instructing traffic to move around either side of the
vehicle.

3.

RIGHT (Position 3).

In this position, the light produces a right arrow

flashing pattern, instructing traffic to move right.

B.

WARN switch.

When this switch is pressed, an alternating pattern is

produced. The two middle lights activate alternately with the two
outside lights on each side. The slide switch will override this
pattern.

C.

AUX switch.

1.

When this switch is pressed, external lamps

alternately flash at a constant rate.  The wiring configuration
determines the flash combination of the external lamps.  The slide
switch will override the external lamp pattern when the AUX
switch is depressed, but will not override the AUX OUT terminal
output.

2.

If connected, the seven-position connector’s AUX

OUT connection provides a ground to activate a user-supplied
relay to control an external device.

D.  FAST switch.

When this switch is pressed, the flash rate of the selected

directional or WARN pattern will increase. The rate of the AUX
switch function is not affected.

E. 

 LOW switch.

When this switch is pressed, all directional patterns are

changed to turn lamps on/off in sequence until a pattern is
completed. The last lamp activated in the pattern will flash three
times. If this switch is operated while the WARN pattern is
activated, the first and sixth lamp activate alternately with the
third and fourth lamp. The selection of this function reduces the
current draw for the directional light assembly’s patterns. The
AUX switch function is not affected by the LOW switch.

F.

Auxiliary Input.

If connected, application of a positive (+) 24-volts to the

AUX IN connection on the seven-position connector produces the
WARN pattern described above. When the positive (+) 24-volts is
removed from the AUX IN connection, the WARN pattern will stop.
Slide switch activation will override the WARN pattern.

V.

SERVICE.

A.

General.

Servicing, other than cosmetic features, should be

performed by a qualified Federal Signal service center. If the
control unit is not working properly, disconnect all electrical
connections starting with the power leads. Remove the control unit
from the mounting bracket. Send the unit to the nearest autho-
rized service center or the Federal Signal service department.

Communication and shipments should be addressed to:

Service Department
Federal Signal Corporation
2645 Federal Signal Drive
University Park, IL 60466

1-800-433-9132

 After servicing is complete, perform a test of all

functions to ensure the control unit is operating properly.

B.

Replacement Parts List.

Description

Part Number

Printed Circuit Board Assembly

2001142-03

Knob, Pushbutton

8573065

Knob, Slide Switch

8536C1041

Bezel, Slide Switch

8573060

Connector, Female, 7-position

140325-05

Connector, Female, 11-position

140325-09

Bracket, Mounting

8573070

Screw, Hex Head, Mounting

7011164-08

Lockwasher, 1/4"

7075078

Chassis

8573247

Cover

8573066