manualshive.com logo in svg
background image

-4-

E. 

 LOW switch.

When this switch is pressed, all directional patterns are

changed to turn lamps on/off in sequence until a pattern is
completed. The last lamp activated in the pattern will flash three
times. If this switch is operated while the WARN pattern is
activated, the first and eighth lamp activate alternately with the
third and sixth lamp. The selection of this function reduces the
current draw for the directional light assembly’s patterns. The
AUX switch function is not affected by the LOW switch.

F.

Auxiliary Input.

If connected, application of a positive (+) 12-volts to the

AUX IN connection on the seven-position connector produces the
WARN pattern described above. When the positive (+) 12-volts is
removed from the AUX IN connection, the WARN pattern will
stop. Slide switch activation will override the WARN pattern.

V.

SERVICE.

A.

General.

Servicing, other than cosmetic features, should be

performed by a qualified Federal Signal service center. If the
control unit is not working properly, disconnect all electrical
connections starting with the power leads. Remove the control unit
from the mounting bracket. Send the unit to the nearest autho-
rized service center or the Federal Signal service department.

Communication and shipments should be addressed to:

Service Department
Federal Signal Corporation
2645 Federal Signal Drive
University Park, IL 60466

1-800-433-9132

 After servicing is complete, perform a test of all

functions to ensure the control unit is operating properly.

B.

Replacement Parts List.

Description

Part Number

Printed Circuit Board Assembly

2001142-02

Knob, Pushbutton

8573065

Knob, Slide Switch

8536C1041

Bezel, Slide Switch

8573060

Connector, Female, 7-position

140325-05

Connector, Female, 11-position

140325-09

Bracket, Mounting

8573070

Screw, Hex Head, Mounting

7011164-08

Lockwasher, 1/4"

7075078

Chassis

8573247

Cover

8573066

the control unit. The LED display simulates the light pattern
being executed by the directional light.

A.

Slide Switch.

1.

LEFT (Position 1).

In this position, the light produces a left arrow

flashing pattern, instructing traffic to move left.

2.

CENTER OUT (Position 2).

In this position, a center out flashing pattern is

produced, instructing traffic to move around either side of the
vehicle.

3.

RIGHT (Position 3).

In this position, the light produces a right arrow

flashing pattern, instructing traffic to move right.

B.

WARN switch.

When this switch is pressed, an alternating pattern is

produced. The four middle lights activate alternately with the two
outside lights on each side. The slide switch will override this
pattern.

C.

AUX switch.

1.

When this switch is pressed, external lamps

alternately flash at a constant rate.  The wiring configuration
determines the flash combination of the external lamps.  The slide
switch will override the external lamp pattern when the AUX
switch is depressed, but will not override the AUX OUT terminal
output.

2.

If connected, the seven-position connector’s AUX

OUT connection provides a ground to activate a user-supplied
relay to control an external device.

D.  

FAST switch.

When this switch is pressed, the flash rate of the selected

directional or WARN pattern will increase. The rate of the AUX
switch function is not affected.

Figure 4.

OFF

290A2542-40B

331102

SignalMaster

TM

FEDERAL SIGNAL CORPORATION

WARN

AUX

FAST

LOW

Содержание SIGNALMASTER 331102

Страница 1: ...ctive directional signals left arrow right arrow and center out An alternating flash pattern produces a warning signal for use when a directional signal may not be appropriate In addition an auxiliary flash pattern alternately flashes the external lamps The directional and alternating flash patterns can also be selected to operate faster or with decreased current draw The slide switch overrides th...

Страница 2: ...auge wire is used for the AUX IN AUX OUT and DASH LIGHTS connections Using figure 2 as a guide complete this portion of the installation as follows 1 Power Connections CAUTION To avoid damage and ensure proper operation the red and black wires MUST be installed as shown in figure 2 a Strip 1 4 of insulation off of each 14AWG red and black wire See figure 2 Crimp a 0 187 wide spade receptacle on th...

Страница 3: ...te external lamps D Inspection and Final Installation 1 Ensure that there are no loose wire strands or other bare wires which may cause a short circuit Also all wires must be protected from any sharp edges which could eventually cut through the insulation 2 Plug the seven position connector into the mating connector on the control unit and apply pressure until it locks into place 3 Plug the eleven...

Страница 4: ... Circuit Board Assembly 2001142 02 Knob Pushbutton 8573065 Knob Slide Switch 8536C1041 Bezel Slide Switch 8573060 Connector Female 7 position 140325 05 Connector Female 11 position 140325 09 Bracket Mounting 8573070 Screw Hex Head Mounting 7011164 08 Lockwasher 1 4 7075078 Chassis 8573247 Cover 8573066 the control unit The LED display simulates the light pattern being executed by the directional l...