Testing the Installation

LIGHT HAZARD: To be an effective warning device, an emergency warning system produces 

bright light that can be hazardous to your eyesight when viewed at a close range. Do not stare 

directly into the lights at a close range, or permanent damage to your eyesight may occur.

After testing the installation, test the emergency warning system to ensure that it is operating properly. 

Also test all vehicle functions, including horn operation, vehicle safety functions, and vehicle lighting 

systems to ensure proper operation. Ensure that the installation has not affected the vehicle operation or 

changed any vehicle safety functions or circuits. 
Do not test the vehicle’s light system while driving. Operating the vehicle warning systems may pose 

a hazard to the operator and other drivers if the systems do not function as expected. Test the vehicle 

only in a controlled environment. After testing is complete, provide a copy of these instructions to the 

instructional staff and all operating personnel. 

Getting Technical Support

For technical support, please contact:
Federal Signal Corporation  

Service Department 

Phone: 1-800-433-9132 

Email: [email protected]

Getting Repair Service

The Federal Signal factory provides technical assistance with any problems that cannot be handled 

locally. Any product returned to Federal Signal for service, inspection, or repair must be accompanied 

by a Return Material Authorization (RMA). Obtain a RMA from a local Distributor or Manufacturer’s 

Representative. Provide a brief explanation of the service requested, or the nature of the malfunction. 
Address all communications and shipments to the following: 

Federal Signal Corporation  

Service Department  

2645 Federal Signal Dr.  

University Park, IL 60484-3167

Limited Warranty

 

This product is subject to and covered by a limited warranty, a copy of which can be found at  

www.fedsig.com/SSG-Warranty. A copy of this limited warranty can also be obtained by written request 

to Federal Signal Corporation, 2645 Federal Signal Drive, University Park, IL 60484, email to info@fedsig.

com or call +1 708-534-3400. 
This limited warranty is in lieu of all other warranties, express or implied, contractual or statutory, 

including, but not limited to the warranty of merchantability, warranty of fitness for a particular purpose 

and any warranty against failure of its essential purpose. 

Содержание SignalMaster 330104 SMC1

Страница 1: ...operated safely under all driving conditions Do not attempt to activate or deactivate light control while driving in a hazardous situation This product controls high intensity lighting devices To prev...

Страница 2: ...r use when a directional signal may not be appropriate One pattern can be selected from the ten patterns available which include seven standard patterns and three patterns that are compliant with CAC...

Страница 3: ...Bracket 8573070 2 Lockwasher Ext Tooth 1 4 inch 7075A007 2 Screw Hex Head 1 4 20 TAPTITE 7011164 08 Installing the SignalMaster Light Bar Install the light assembly as described in the instructions i...

Страница 4: ...ed as shown here if it better suits your mounting requirements NOTE Only oneBracket is supplied Thread Forming Screws Installer Supplied Connecting Power to the Controller HIGH CURRENT ARCING Do not c...

Страница 5: ...other electrical connections have been made To run between the fuse and the SignalMaster use a properly sized red wire For wire gauge recommendations see Table 5 5 Select a termination point for the...

Страница 6: ...en Orange Violet Gray Yellow Blue 14 AWG Ground Connection Binding Screw for Ground Wire 18 AWG Minimum Power Wire from Controller Connect to Ignition or Battery Draws 7 mA 0 007 A at Battery Red Red...

Страница 7: ...can select after the installation and wiring of the SignalMaster system is complete For the functions of the controller buttons see Figure 3 and Operating the SignalMaster Controller on page 9 Figure...

Страница 8: ...heads on the SignalMaster Selecting a Standard Warn Pattern In the default Standard Mode each time the WARN button is pressed the active warn pattern changes to the next in the sequence See Table 5 o...

Страница 9: ...ly or if any of the lamps remain illuminated when the control is off disconnect the power connector from the controller and contact the nearest service center Failure to follow these safety precaution...

Страница 10: ...tting Technical Support For technical support please contact Federal Signal Corporation Service Department Phone 1 800 433 9132 Email empserviceinfo fedsig com Getting Repair Service The Federal Signa...

Страница 11: ...o order replacement parts call Customer Support at 1 800 264 3578 7 a m to 5 p m Monday through Friday CT or contact your nearest distributor Table 8 Replacement Parts Qty Description Part No 1 Contro...

Страница 12: ...y Park Illinois 60484 3167 www fedsig com Customer Support Police Fire EMS 800 264 3578 1 708 534 3400 Work Truck 800 824 0254 1 708 534 3400 Technical Support 800 433 9132 1 708 534 3400 Copyright 19...

Отзывы: