Unpacking the Product

After unpacking the product, inspect it for damage that may have occurred in transit. If it has been damaged 

or is missing a part, do not attempt to install or operate it. File a claim immediately with the carrier, stating 

the extent of the damage. Carefully check all envelopes, shipping labels and tags before removing or 

destroying them. If you are missing any parts, contact Customer Support at 1-800-264-3578, 7 a.m. to  

5 p.m., Monday through Friday (CT).

Programming the Light Bar

LIGHT HAZARD: 

To be an effective warning device, this product produces bright light that can be 

hazardous to your eyesight when viewed at a close range. Do not stare directly into this lighting 

product at a close range, or permanent damage to your eyesight may occur.

Before permanently installing the Serial Interface Module (described on page 8), test and program the 

light bar. Each mode patterns is programmed independently. If you want to program the light bar after you 

connect a progressive slide switch, the programming sequence must be MODE 3, MODE 2, MODE 1, and 

then INTERSECTION.
A number of different flash patterns are available for the three modes of light bar operation. When you use 

the SW1 flash pattern button, the light bar momentarily turns off before flashing the next pattern. To cycle up 

or down through the flash patterns, set SW2 Switch 5 as shown in Table 1 on page 3.
In addition, the FRONT/REAR light heads can be set for +BAT cutoff or enable. The INTERSECTION mode 

has one of three options: HIGH (+BAT maintained), TAP II (push-on/push-off) or an 8-SECOND TIMEOUT. 
The SignalMaster

®

 can also be set for INTERNAL or EXTERNAL control. See Table 1. 

Wiring the Interface Module for Testing and Programming

To wire the Interface Module for programming before permanent installation:

1. 

Connect the serial cable from the light bar to the J3 output jack of the Interface Module. See Figure 1.

Figure 1 Connectors and switches on the Serial Interface Module

J3 Connector for Serial 

Cable from Light Bar

J1 Connector for 24-Conductor Cable 

Supplied with Serial Interface Module

SW2 DIP Switches (See 

Table 1 on page 3.)

Programming Header for Cloning Flash 

Patterns from Vehicle to Vehicle (see the 

instructions included with the programmer.))

SW1 Button for Selecting Flash Patterns

290A7803

2. 

Connect the three-foot-long, 24-conductor cable to the J1 input connector of the Interface Module. 

3. 

Connect the white wire from the supplied J1 cable harness on the Interface Module to a 1 A fuse. 

Содержание Serial Interface Module

Страница 1: ...CONTROLS can be operated safely under all driving conditions If a vehicle seat is temporarily removed verify with the vehicle manufacturer if the seat needs to be recalibrated for proper airbag deploy...

Страница 2: ...TION A number of different flash patterns are available for the three modes of light bar operation When you use the SW1 flash pattern button the light bar momentarily turns off before flashing the nex...

Страница 3: ...st sequence SCENE LIGHT is unavailable with this switch setting Table 1 SW 2 DIP switch settings in the Interface Module SW2 Switch Number Switch Setting SIgnalMaster Function and Control Wires See th...

Страница 4: ...e MODE 2 with BAT b Push and release SW1 until the flash pattern you want displays c Remove BAT from MODE 2 4 Program MODE 1 a Activate MODE 1 with BAT b Push and release SW1 until the flash pattern y...

Страница 5: ...perational Settings SW2 SW7 SW8 HIGH BAT maintained OFF up OFF up TAP II BAT push on push off ON down OFF up 8 SECOND TIMEOUT activated by BAT OFF up ON down Selecting External SignalMaster Control Th...

Страница 6: ...agram 290A7693 Light Bar FSC Serial Interface Module Part 8583446 Reference Serial CAT5 Control Cable Black 10 AWG Red 10 AWG User Supplied Fuse 40 A Battery Black White Black White 16 AWG Ignition 1...

Страница 7: ...ature to function Alley Lights Applying 12 Vdc to the LEFT or RIGHT ALLEY control leads activates the corresponding alley light Takedown Applying 12 Vdc to the Takedown control lead illuminates the TA...

Страница 8: ...Light Bar on page 3 Installing the Serial Interface Module INSTALLATION PRECAUTIONS Do not install the Interface Module in an area where it cannot dissipate heat into the air Do not mount the unit ne...

Страница 9: ...in relief Wiring the SignalMaster LIGHT HAZARD To be an effective warning device this product produces bright light that can be hazardous to your eyesight when viewed at a close range Do not stare dir...

Страница 10: ...ranking position 290A7695 Power 12 Vdc 1 A 1 A 1 A 1 A 1 A 1 A 1 A 1 A 1 A 1 A 1 A 1 A 1 A 1 A 1 A 1 A 1 A 1 A 1 A 1 A 1 A 1 A Mode 2 Mode 1 Steady Burn Intersection Flash Takedown Alley Right Alley L...

Страница 11: ...le Orange Black Rear Cutoff Enable White Black Red Low Power Black White Red Light Bar Test Red 1 Left Green 2 3 Green Black White Orange Green 4 Orange 5 Blue red 6 Red Green 7 8 Right White Red 1 A...

Страница 12: ...deral Signal Corporation Service Department 2645 Federal Signal Dr University Park IL 60484 3167 Limited Warranty This product is subject to and covered by a limited warranty a copy of which can be fo...

Отзывы: