background image

Installation and Programming Instructions for the Serial Interface Module

10

Serial Interface Module 

Federal Signal

 www.fedsig.com

Figure 4 SignalMaster control functions wired to 12 Vdc for Internal Control (factory default)

Blue/Black

Red/Black

Orange/Red

Green/Black

White/Black

Green/White

Orange/Black

White/Black/Red

Low Power

Black/White/Red

Light Bar Test

Red

SignalMaster Left

Green

Green/Black/White

Orange/Green

Orange

Blue/Red

Red/Green

White/Red

Ignition Power

White

Black

Ground 1

Black/White

Ground 2

Ignition*

* Ignition power includes power in the cranking position

290A7695

Power (+12 Vdc)

1 A

1 A

1 A

1 A

1 A

1 A

1 A

1 A

1 A

1 A

1 A

1 A

1 A

1 A

1 A

1 A

1 A

1 A

1 A

1 A

1 A

1 A

Mode 2

Mode 1

Steady Burn

Intersection

Flash Takedown/Alley

Right Alley

Left Alley

Front Cutoff/Enable

Rear Cutoff/Enable

Black/Red

Mode 3

Takedown

Blue/White

Blue

Red/Wite

SignalMaster Center

SignalMaster Right

SignalMaster  Warn 1

SignalMaster Warn 2

SignalMaster Warn 3

SignalMaster Warn 4

Fast

J1 Cable to

Serial Interface

Module

(Or Scene Light, Left with SW-2 Switch 3

Down [On] in the Serial Interface Module)

(Or Scene Light, Right with SW-2 Switch 3

Down [On] in the Serial Interface Module)

Available in Light Bars with 

Spectralux technology 

(Valor and Vision SLR)

Available in Light Bars with 

Spectralux technology 

(Valor and Vision SLR)

Содержание Serial Interface Module

Страница 1: ...CONTROLS can be operated safely under all driving conditions If a vehicle seat is temporarily removed verify with the vehicle manufacturer if the seat needs to be recalibrated for proper airbag deploy...

Страница 2: ...TION A number of different flash patterns are available for the three modes of light bar operation When you use the SW1 flash pattern button the light bar momentarily turns off before flashing the nex...

Страница 3: ...st sequence SCENE LIGHT is unavailable with this switch setting Table 1 SW 2 DIP switch settings in the Interface Module SW2 Switch Number Switch Setting SIgnalMaster Function and Control Wires See th...

Страница 4: ...e MODE 2 with BAT b Push and release SW1 until the flash pattern you want displays c Remove BAT from MODE 2 4 Program MODE 1 a Activate MODE 1 with BAT b Push and release SW1 until the flash pattern y...

Страница 5: ...perational Settings SW2 SW7 SW8 HIGH BAT maintained OFF up OFF up TAP II BAT push on push off ON down OFF up 8 SECOND TIMEOUT activated by BAT OFF up ON down Selecting External SignalMaster Control Th...

Страница 6: ...agram 290A7693 Light Bar FSC Serial Interface Module Part 8583446 Reference Serial CAT5 Control Cable Black 10 AWG Red 10 AWG User Supplied Fuse 40 A Battery Black White Black White 16 AWG Ignition 1...

Страница 7: ...ature to function Alley Lights Applying 12 Vdc to the LEFT or RIGHT ALLEY control leads activates the corresponding alley light Takedown Applying 12 Vdc to the Takedown control lead illuminates the TA...

Страница 8: ...Light Bar on page 3 Installing the Serial Interface Module INSTALLATION PRECAUTIONS Do not install the Interface Module in an area where it cannot dissipate heat into the air Do not mount the unit ne...

Страница 9: ...in relief Wiring the SignalMaster LIGHT HAZARD To be an effective warning device this product produces bright light that can be hazardous to your eyesight when viewed at a close range Do not stare dir...

Страница 10: ...ranking position 290A7695 Power 12 Vdc 1 A 1 A 1 A 1 A 1 A 1 A 1 A 1 A 1 A 1 A 1 A 1 A 1 A 1 A 1 A 1 A 1 A 1 A 1 A 1 A 1 A 1 A Mode 2 Mode 1 Steady Burn Intersection Flash Takedown Alley Right Alley L...

Страница 11: ...le Orange Black Rear Cutoff Enable White Black Red Low Power Black White Red Light Bar Test Red 1 Left Green 2 3 Green Black White Orange Green 4 Orange 5 Blue red 6 Red Green 7 8 Right White Red 1 A...

Страница 12: ...deral Signal Corporation Service Department 2645 Federal Signal Dr University Park IL 60484 3167 Limited Warranty This product is subject to and covered by a limited warranty a copy of which can be fo...

Отзывы: