Pathfinder
®
Federal Signal
www.fedsig.com
Testing the Pathfinder® Installation
28
Table 7 Pathfinder
®
Switch Default Programming
Switch
Default Function
Slide Switch 1
Relays 1 and 2 ON
Light Bar – Pattern 26, Front Cutoff
ILS –Rear Pattern 26
CNSM –Rear Pattern 26
Slide Switch 2
Relays 1-4 ON
Horn Ring Transfer
Light Bar – Pattern 26
ILS – Front Pattern 23, Rear Pattern 26
CNSM – Front Pattern 23, Rear Pattern 26
Slide Switch 3
Relays 1-5 ON
Horn Ring Transfer, Siren Enabled
Light Bar – Pattern 27, Flash White Enable
ILS – Front and Rear Pattern 25, Flash White Enable
CNSM – Front and Rear Pattern 25, Flash White Enable
Rotary – Radio
Radio Re-Broadcast
Rotary – Manual
Standby
Rotary – Wail*
Wail
Horn Ring Transfer
Rotary – Yelp*
Yelp
Horn Ring Transfer
Rotary – HF*
Horn Siren Control
Rotary – Tone 1*
Priority
Rotary – Tone 2*
Dual Tone (Wail/Yelp)
Volume Switch
Turns Off Keypad Backlighting
*Siren Tones Dependent on Slide Switch 3
Table 8 Pathfinder Button Default Programming
Button
Default Function
BTN 1
Step 1 – Left Alley (LB), Relay 7 ON
Step 2 – Flood Left (LB/ILS/CNSM), Relay 7 ON
BTN 2
Step 1 –Takedown (LB/ILS/CNSM), Relay 9 ON
Step 2 – Full Flood (LB/ILS/CNSM), Relay 9 ON
BTN 3
Step 1 – Right Alley (LB), Relay 8 ON
Step 2 – Flood Right (LB/ILS/CNSM), Relay 8 ON
BTN 4
Dim (LB/ILS/CNSM)
BTN 5
Cruise (LB/ILS/CNSM)
BTN 6
Rear Cut (LB/ILS/CNSM)
BTN 7
Signal Master Step LRCO (LB/ILS/CNSM)
BTN 8
Air Horn
BTN 9
Relay 6 ON (GND) (8 Second Timer)