![Federal Signal Corporation I-IP15 Скачать руководство пользователя страница 7](http://html.mh-extra.com/html/federal-signal-corporation/i-ip15/i-ip15_installation-operation-and-service-manual_548414007.webp)
7
Safety Messages
Description, Specifications, Installation, Operation, and Service Manual
Installation and Service
• After installation or service, test the system to confirm that it is operating properly.
Test the system regularly to confirm that it will be operational in an emergency.
• If future service and operating personnel do not have these instructions to refer to,
the system may not provide the intended audible warning and service personnel
may be exposed to death, permanent hearing loss, or other bodily injury. File these
instructions in a safe place and refer to them periodically. Give a copy of these
instructions to new recruits and trainees. Also give a copy to anyone who is going to
service or repair the Informer15 Speaker.
• To reduce the risk of electric shock, do not perform any servicing other than what
is contained in the operating instructions unless you are qualified to do so. Refer all
servicing to qualified service personnel. Always test the Informer15 Speaker before
using after repairs have been made.
Ethernet Wiring
• Unless shielded or run in conduit, Ethernet wiring must be at least six feet from bare
power wiring or lightning rods and associated wires, and at least six inches from
other wire (for example, antenna wires, doorbell wires, wires from transformers to
neon signs), steam or hot water pipes, and heating ducts.
• Do not place Ethernet wiring or connections in any conduit, outlet or junction box
containing high voltage electrical wiring.
Symbol Definition
_A _V
Indicates to reduce the risk of fire, replace fuse as marked.
Pay careful attention to the notice located on the equipment.
Read and understand the information contained in this manual before
attempting to install or service the siren.