Operations

Informer15 Speaker (Model I-IP15)

Operations

Table 5 Connectors and Jacks for Control Board

JP1

LED Lamp Test

Short pins 1 and 2 to turn on LED lamp

JP2

Inputs

1 – ISO-GND

2 – Input #1

3 – ISO-GND

4 – Input #2

5 – ISO-GND

6 – Input #3

7 – ISO-GND

8 – Input #4

JP3

LED Lamp Output

1 – GND

2 – Power, sw24 Vdc

JP4

Test mode

JP5

Factory Default

Short pins 1 and 2 to restore to factory defaults

JP6

Open Collector Output

1 – Output #1 Open Collector Output

2 – Output #1 +24 Vdc

JP7

POE power output from Ethernet module

1 – POE+

2 – POE-

JP8

Option1 Jumper

Short pins 1 and 2 for Option

JP9

Option2 Jumper

Short pins 1 and 2 for Option

JP11

Serial Port RJ25 6 conductor mod jack

JP12

Controller to Amplifier Interface

JP13

microSD FLASH card holder

Table 6 Connectors and Jacks for Amplifier

JP1

Power Input

JP2

Balanced Audio Input – 10 or 25 Vrms in

JP3

Audio Input Select Jumper (Not used with I-IP15 configuration.)

Jumper 1 and 2 = 25 Vrms input

Jumper 3 and 4 = 10 mVrms input

JP4

Amplifier to Controller Interface

Pin1

(-) Speaker output

Pin2

(+) Speaker output

VR1

Amplifier Gain (For max volume, turn clockwise.)

The following indicators are for troubleshooting purposes only. These indicators are not 

visible when the unit is closed.

Содержание I-IP15

Страница 1: ...ption Specifications Installation Operation and Service Manual 25500494 Rev A0 0918 Printed in U S A Copyright 2018 Federal Signal Corporation Informer15 Speaker Model I IP15 IP Enabled Indoor Outdoor Speaker ...

Страница 2: ...y is in lieu of all other warranties express or implied contractual or statutory including but not limited to the warranty of merchantability warranty of fitness for a particular purpose and any warranty against failure of its essential purpose 2645 Federal Signal Drive University Park Illinois 60484 3167 www fedsig com Customer Support 800 548 7229 1 708 534 3400 Technical Support 800 524 3021 1 ...

Страница 3: ...ew 8 Features 9 Ordering Information 10 Specifications 10 Installation 11 Flat Surface Mounting 12 Opening the Housing 13 Wiring to the Control Board 13 Closing the Housing 15 Operations 16 Testing 17 Maintenance 18 Ordering Replacement Parts 18 Getting Service 18 Figures Figure 1 Depth and Height of Informer15 Speaker 12 Figure 2 I IP15 Controller Board 15 ...

Страница 4: ...ctrical Requirements 10 Table 3 Environmental 10 Table 4 Physical 11 Table 5 Connectors and Jacks for Control Board 16 Table 6 Connectors and Jacks for Amplifier 16 Table 7 Visual Indications for Control Board 17 Table 8 Visual Indications for Amplifier 17 Table 9 Replacement Parts 18 ...

Страница 5: ...s near sirens Activating the Informer15 Speaker may not result in people taking the desired actions if those to be warned are not properly trained about the meaning of warning sounds Users should follow FEMA recommendations and instruct those to be warned of correct actions to be taken After installation service or maintenance test the system to confirm that it is operating properly Test the syste...

Страница 6: ...acht Council Inc and or ANSI NFPA 302 Fire Protection Standard for Pleasure and Commercial Motor Craft For optimum sound distribution do not install this speaker where objects would block any portion of the front of the Informer15 Speaker Do not paint the Informer15 Speaker No finish or coating is required Paint may obstruct the sound output reducing the effectiveness of the horn Establish a proce...

Страница 7: ...ctric shock do not perform any servicing other than what is contained in the operating instructions unless you are qualified to do so Refer all servicing to qualified service personnel Always test the Informer15 Speaker before using after repairs have been made Ethernet Wiring Unless shielded or run in conduit Ethernet wiring must be at least six feet from bare power wiring or lightning rods and a...

Страница 8: ...o four external switches to activate predefined alert events The Informer15 can be programmed and configured as a standalone device to only use the inputs to activate the Informer15 This may be useful if the location has no network connectivity but where voice and tone alerts from locally activated inputs is required The Informer15 can be networked later and the activations can be brought into the...

Страница 9: ...ol Each device can be remotely configured for volume and noise level adjustments Speaker as microphone for talk back feature Alerts can be sent to single devices groups or zones or all devices Wall mount Four local alarm initiation inputs to activate unit locally or standalone operation Momentary mode contact closure sounds alarm for programmed duration Continuous mode sounds alarm for duration of...

Страница 10: ...ximum 30 V or 100 mA maximum speaker provides 24 Vdc 20 mA maximum for external relay Ethernet Port IEEE 802 3 10 100 Base T connection with PoE 802 3at Type 2 25 5 W Alarm Initiating Inputs Four optically Isolated Inputs Audio Storage Warning siren audio seven factory installed tones Wail Steady Alternate Wail Alternate Steady Pulsed Wail Pulsed Steady Auxiliary Chime Prerecorded files up to 4000...

Страница 11: ...e experienced electricians in accordance with national and local electrical codes acting under the direction of the installation crew safety foreman should perform installation Property damage serious injury or death could occur if an accumulation of water snow dust etc resides in the speaker projector severely reducing or preventing operation of this device Mount the unit so speaker projector is ...

Страница 12: ...e See Figure 1 for mounting hole locations and dimensions Before drilling holes in any surface ensure that both sides of surface are clear of items that could be damaged 3 Secure the unit to a wooden mounting surface with 10 x 1 inch wood screws If mounting on a metal surface drill 13 64 inch diameter holes and secure the unit with 10 screws lock washers and nuts 4 Route wires through the 1 2 inch...

Страница 13: ...e Informer15 Speaker 2 JP13 is used to provide tone messages into the IP15 via microSD memory card 3 If local activations are required use JP2 The Alarm Initiation Inputs are activated by shorting the input to the ISO GND next to it usually through an normally open switch or normally open dry relay contact NOTE Momentary mode contact closure sounds alarm for typical programmed duration Continuous ...

Страница 14: ...e programmed default timeout occurs Until the CANCEL or RESET command is received You can configure the open collector relay output to open close and cycle based on a pre programmed sequence The open collector relay output can also be configured to turn on when PA VOIP is active Refer to Informer IP Setup Program and User Manual for programming your Informer 6 If using a scrolling message board us...

Страница 15: ...Test JP1 JP6 JP8 JP9 JP4 JP5 LAN Interface Closing the Housing To close the housing do the following 1 Verify that the cover gasket is in the groove around the perimeter of the rear cover 2 If the front of the unit was removed install the visual indicator cable and attach the cover to the Informer15 Speaker Property damage serious injury or death could occur if the housing is not closed properly T...

Страница 16: ...odule 1 POE 2 POE JP8 Option1 Jumper Short pins 1 and 2 for Option JP9 Option2 Jumper Short pins 1 and 2 for Option JP11 Serial Port RJ25 6 conductor mod jack JP12 Controller to Amplifier Interface JP13 microSD FLASH card holder Table 6 Connectors and Jacks for Amplifier JP1 Power Input JP2 Balanced Audio Input 10 or 25 Vrms in JP3 Audio Input Select Jumper Not used with I IP15 configuration Jumpe...

Страница 17: ... the OSHA Sound Level Standard 29 CFR 1910F should not be exceeded 1 After installation is complete test the system to verify that each speaker operates satisfactorily 2 After completion of initial system test establish a program for periodic testing of this device 3 Provide a copy of these instructions for the Safety Engineer system operator s and maintenance personnel Safety Message to Operators...

Страница 18: ...ntenance personnel should not be obscured if the exterior of device is painted Periodically inspect this device to verify that there are no foreign substances in or in front of the speaker which will reduce its notification effectiveness Periodic evaluation on the performance of the unit should be conduct at regular intervals In the event a volume adjustment or other repair is required be sure to ...

Страница 19: ...2645 Federal Signal Drive University Park Illinois 60484 3167 www fedsig com Customer Support 800 548 7229 1 708 534 3400 Technical Support 800 524 3021 1 708 534 3400 ...

Страница 20: ...2645 Federal Signal Drive University Park Illinois 60484 3167 www fedsig com Customer Support 800 548 7229 1 708 534 3400 Technical Support 800 524 3021 1 708 534 3400 ...

Отзывы: