Chapter 3: Wiring the e-Q2B Siren System
e-Q2B Siren System
19
2.
To provide strain relief, secure the cables with installer-supplied clamps and hold-downs.
3.
Insert the modular connector at the end of each cable into one of the three serial ports.
Figure 3.3 Serial port locations
30 AMP
FUSE
RED
(+BAT)
WHT/RED
(IGN)
BLK
(-BAT)
REMOTE MIC
RADIO
PARK
2
A/H
4
AUX
6
8
BRAKE
1
33
RING
GRND
10
CYCLE
12
HORN
5
RMBLR
ENBL
RMBLR
RADIO
7
RADIO
9
RADIO
11
FEDERAL SIGNAL
CONVERGENCE NETWORK
SPEAKER OUTPUT
-POWER
-OUTPUT
-LOAD
LIMIT-
SHORT-
THERMAL-
− BLK
− GRN
+ WHT
+ RED
RESERVE ONE SERIAL PORT
FOR THE CONNECTION TO
THE CONTROL HEAD. (SEE
PAGE 28.)
290A6803
Connecting the Foot Switches for Cycle, Brake, and Air Horn
For input connections for the Model EQ2B-200-RCFD, see Figure 3.4.
The
CYCLE
,
BRAKE
, and
AIR HORN
functions are activated either by control head buttons or by
remotely located foot switches. The foot switches connect to the front of the siren amplifier.
Figure 3.4 Foot switch connections
REMOTE MIC
RADIO
PARK
2
A/H
4
AUX
6
8
BRAKE
1
33
RING
GRND
10
CYCLE
12
HORN
5
RMBLR
ENBL
RMBLR
RADIO
7
RADIO
9
RADIO
11
AIR HORN FOOT SWITCH
BRAKE FOOT SWITCH
GROUND
CYCLE FOOT SWITCH
BAT −GND
12-POSITION
TENSION CLAMP
CONNECTOR
P/N 140584-12
INSULATION STRIPPED
0.275 in (0.7 mm)
1. INSERT SCREWDRIVER
TO OPEN TENSION CLAMP.
2. SLIP WIRE INTO CONNECTOR.
3. REMOVE SCREWDRIVER TO
LOCK CLAMP ON WIRE.
290A6804
Содержание e-Q2B
Страница 2: ...blank page ...