12
Installation and Maintenance Instructions
Model 371LED-120 Rotating Light
5.
Tighten the clamping screw. The maximum tightening
torque is 7.0 in-lb (0.8 N
•
m).
6.
Connect the earth ground to the terminal block.
7.
Reassemble the light and test it for proper operation.
Figure 4
Connecting leads to the terminal block
0.28"
(7mm)
TERMINAL
BLOCK
PLASTIC DOME
LED / MOTOR
MODULE
REFLECTOR
DIECAST
BASE
DIECAST RING
#10 PHILLIPS
SCREW (3)
FACTORY-SUPPLIED
LEADS FROM
TERMINAL BLOCK