2
SECTION II
SPECIFICATIONS
Power Requirements*
Siren Motor .................................................. 48V (DC or full wave
rectified AC) 100 amps (nom.)
Rotator Motor ............................................... 48V (DC or full wave
rectified AC) 1 amp (nom.)
Wiring
Siren Motor .................................................. 2 AWG
Rotator Motor ............................................... 14 AWG
Motor Type
Siren ............................................................ Series Wound DC 6.5 Hp
Rotator ......................................................... Permanent Magnet DC 1/8 Hp
Signal Information
Signal
Frequency Range
Sweep Rate
STEADY
790Hz
N.A.
WAIL
470 - 790Hz
10 sec.
FAST WAIL
600 - 790Hz
3.6 sec.
Signal Duration ........................................... 3 min. (programmable)
Sound Output (SPL) ............................................... /-1dBc (on axis)
at 100' (30.5m.)
Rotation .................................................................. 3 RPM
Dimensions (HWD) ................................................. 62" x 37" x 41"
1574mm x 940mm x 1041mm
Shipping Weight ..................................................... 450 pounds (204kg.)
Siren Weight ........................................................... 420 pounds (191kg.)
Operating Temperature .......................................... -30
C to +60ºC**
* Power requirements refers to the power supplied by the batteries or optional AC operation
with battery back up.
** The siren can operate throughout this temperature range provided the battery temperature
is maintained at -18ºC or higher.