Limited Warranty

 

 

The  Federal  Warning  Systems  Division  of 

Federal  Signal  Corporation 

warrants  each 

new product to be free from defects in material and workmanship, under normal use and 
service, for a period of two years on parts replacement and factory-performed labor (one 
year  for  Informer,  EAS,  and  Federal  software  products)  from  the  date  of  delivery  to  the 
first  user-purchaser.    Federal  Warning  Systems  warrants  every  2001  &  Eclipse  Siren 
(Top  of  pole  only)  to  be  free  from  defects  in  material,  per  our  standard  warranty,  under 
normal use and service for a period of five years on parts replacement. 
 
During this warranty period, the obligation of  Federal is limited to repairing or  replacing, 
as  Federal  may  elect,  any  part  or  parts  of  such  product  which  after  examination  by 
Federal discloses to be defective in material and/or workmanship. 
 
Federal will provide warranty for  any unit which is delivered, transported prepaid,  to the 
Federal  factory  or  designated  authorized  warranty  service  center  for  examination  and 
such examination reveals a defect in material and/or workmanship. 
 
This  warranty  does  not  cover  travel  expenses,  the  cost  of  specialized  equipment  for 
gaining  access  to  the  product,  or  labor  changes  for  removal  and  re-installation  of  the 
product.  The  Federal  Signal  Corporation  warranty  shall  not  apply  to  components  or 
accessories that have a separate warranty by the original manufacturer, such as, but not 
limited to, batteries. 
 
Federal will provide on-site warranty service during the first 60-days after the completion 
of  the  installation,  when  Federal  has  provided  a  turn-key  installation  including 
optimization and/or commissioning services. 
 
This  warranty  does  not extend  to  any  unit which  has  been  subjected  to abuse,  misuse, 
improper installation or which has been inadequately maintained, nor to units which have 
problems  related  to  service  or  modification  at  any  facility  other  than  Federal  factory  or 
authorized  warranty  service  centers.    Moreover,  Federal  shall  have  no  liability  with 
respect  to  defects  arising  in  Products  through  any  cause  other  than  ordinary  use  (such 
as, for example, accident, fire, lightning, water damage, or other remaining acts of god). 

 
THERE ARE NO OTHER WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING BUT 
NOT LIMITED TO, ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS 
FOR  A  PARTICULAR  PURPOSE.    IN  NO  EVENT  SHALL  FEDERAL  BE  LIABLE  FOR 
ANY  LOSS  OF  PROFITS  OR  ANY  INDIRECT  OR  CONSEQUENTIAL  DAMAGES 
ARISING OUT OF ANY SUCH DEFECT IN MATERIAL WORKMANSHIP

 

 
 

 

 

 

 

 

2645 Federal Signal Drive, University Park, IL 60466 

Phone: (800) 524-3021 Fax: (708) 534-4865 

Website: 

http://www.federalwarningsystems.com

 

 

Содержание 2001-130

Страница 1: ...FEDERAL SIGNAL CORPORATION 2001 130 ELECTRO MECHANICAL SIREN INSTALLATION AND OPERATING INSTRUCTIONS Copyright 2007 Federal Signal Corporation 255369E 2 13 ...

Страница 2: ...nges to devices and specifications detailed in the manual at any time in order to improve reliability function or design The information in this book has been carefully checked and is believed to be accurate however no responsibility is assumed for any inaccuracies ...

Страница 3: ...erative that knowledgeable people who are provided with the necessary information are available at all times to authorize the activation of the sirens When sirens are used out of doors people indoors may not be able to hear the warning signals Separate warning devices or procedures may be needed to effectively warn people indoors The sound output of sirens is capable of causing permanent hearing d...

Страница 4: ...ce test the siren system to confirm that it is operating properly Test the system regularly to confirm that it will be operational in an emergency If future service personnel do not have these warnings and all other instructions shipped with the equipment to refer to the siren system may not provide the intended audible warning and service personnel may be exposed to death permanent hearing loss o...

Страница 5: ...s for removal and re installation of the product The Federal Signal Corporation warranty shall not apply to components or accessories that have a separate warranty by the original manufacturer such as but not limited to batteries Federal will provide on site warranty service during the first 60 days after the completion of the installation when Federal has provided a turn key installation includin...

Страница 6: ...G Read and understand the information contained in this manual before attempting to install or service the siren Pay careful attention to the following notices located on the equipment NOTICES EXTERNALLY PLACED ...

Страница 7: ... Siren Description 1 1 4 Signal Description 1 SECTION II SPECIFICATIONS 2 1 Specifications 2 SECTION III INSTALLATION 3 1 Siren Location 3 3 2 Siren Installation 4 3 3 Siren Wiring 6 3 4 Pre operation Checkout 8 SECTION IV SERVICE AND MAINTENANCE 4 1 General 9 4 2 Inspection 9 4 3 Corrective Maintenance 10 ...

Страница 8: ...y to the siren from a 208 220 or 240 optionally 480VAC line Two motors are used to create the siren signals One motor rotates the siren assembly The second motor which produces the sound energy is attached to a stator with a rotor mounted on the motor shaft concentric to the stator The rotor and stator each contain one row of ports As the motor rotates the rotor air is drawn into the rotor and pas...

Страница 9: ...Y 790Hz N A WAIL 470 790Hz 10 sec FAST WAIL 600 790Hz 3 6 sec Signal Duration 3 min programmable Sound Output SPL 130dBc 1dBc on axis at 100 30 5m Rotation 3 RPM Dimensions HWD 62 x 37 x 41 1574mm x 940mm x 1041mm Shipping Weight 450 pounds 204kg Siren Weight 420 pounds 191kg Operating Temperature 30 C to 60ºC Power requirements refers to the power supplied by the batteries or optional AC operatio...

Страница 10: ...iren Optimum sound propagation conditions exist when there are no obstructions in the sound path the terrain is flat and the air is calm Under these conditions each time the distance from the siren is doubled the sound level decreases by approximately 10dB For example the sound level at 100 feet 30 5m from a 2001 130 siren is 130dB At 200 feet 61m the level drops to 120dB at 400 feet 122m the soun...

Страница 11: ... possible to install a siren in almost any situation If the installations in this paragraph are not suitable modification of one of the configurations may be practical A siren is typically installed 40 50 ft above the ground If the installation is located less than 40 ft above the ground the sound intensity at close range may increase but at the same time the effective range of the siren may be re...

Страница 12: ... WARNING above 4 Raise the siren to the necessary height and lower it over the pole 5 Adjust the legs and insert shims if necessary between the siren legs and pole The legs adjust to a diameter between 7 53 and 12 25 See Figure 3 3 Bolt the siren to the pole using two 5 8 galvanized lag bolts with washers and split lockwashers per leg At least four inches of lag bolt must be screwed into the pole ...

Страница 13: ...ended install location Locate the platform at the siren installation site The platform must be properly anchored to the mounting surface WARNING The hoisting bracket does not have sufficient strength to support the combined weight of the siren and a platform Therefore do NOT lift the siren and platform together using the bracket as a lifting point 2 Hoist the siren to the installation site using t...

Страница 14: ...t of the controller provides positive power to the rotator motor One 2 AWG black wire provides a common 48VDC negative ground between the ground plane of the control cabinet and siren motors See Figure 3 6 for the wire connections in the 2001 130 Consult the manual for the controller being utilized to connect the wires from the head Figure 3 6 Wiring for Rotator Motor All wire connections should b...

Страница 15: ... tests or maintenance on the siren A Make sure that all air intakes and sound outlets are not obstructed B Make sure all connections in the Control Unit Battery Box are correct and properly tightened C Activate all siren tones to verify they are operating properly The siren should remain rotating during all alert tones D After the installation is complete and it has been established that the siren...

Страница 16: ... Battery Box before inspecting or maintaining the siren 4 2 INSPECTION Test the 2001 130 siren for proper operation at least once a month A daily test at noon curfew or other selected time is preferred This not only enhances the usefulness of the siren but also instills public confidence in the reliability of the warning system In order to minimize the possibility of siren failure annual inspectio...

Страница 17: ...ing However after the horn is moving the scale indication should decrease to some force within the specified range If the scale does not indicate between 25 and 30 pounds 11 and 13kg the drive band requires adjustment 2 To adjust the drive band a Perform steps a b and c in paragraph 4 3 A 1 above to determine if a drive band adjustment is necessary b Ensure that power to the siren is disconnected ...

Страница 18: ... Brush Holder Assy 5 Insert the replacement brush into the brush holder Connect the lead wires to the brush holder C Collector Ring Removal 1 Remove the brush assembly as described above 2 Disconnect the three wires from the terminal block TB5 inside the rotator housing and begin feeding wires up into the siren shaft see Figure 4 2 3 Federal suggests that the rotator drive band be loosened as desc...

Страница 19: ...tor housing assembly 14 Replace the back panel D Rotator Motor Replacement 1 Remove the two rotator housing panels see Figure 4 2 2 Replace the rotator motor Approximately a 1 64 gap between the teeth of the two gears is required to avoid binding Re tighten rotator motor bolts to a torque of 45 in lbs 3 Wire rotator motor and terminal block as shown in Figure 3 6 4 Grease all gear surfaces with Mo...

Страница 20: ...13 Figure 4 9 2001 130 Final Assembly Sheet 1 ...

Страница 21: ...14 Figure 4 10 2001 130 Final Assembly Sheet 2 ...