Страница 1: ...FEDERAL SIGNAL CORPORATION 2001 130 ELECTRO MECHANICAL SIREN INSTALLATION AND OPERATING INSTRUCTIONS Copyright 2007 Federal Signal Corporation 255369E 2 13 ...

Страница 2: ...nges to devices and specifications detailed in the manual at any time in order to improve reliability function or design The information in this book has been carefully checked and is believed to be accurate however no responsibility is assumed for any inaccuracies ...

Страница 3: ...erative that knowledgeable people who are provided with the necessary information are available at all times to authorize the activation of the sirens When sirens are used out of doors people indoors may not be able to hear the warning signals Separate warning devices or procedures may be needed to effectively warn people indoors The sound output of sirens is capable of causing permanent hearing d...

Страница 4: ...ce test the siren system to confirm that it is operating properly Test the system regularly to confirm that it will be operational in an emergency If future service personnel do not have these warnings and all other instructions shipped with the equipment to refer to the siren system may not provide the intended audible warning and service personnel may be exposed to death permanent hearing loss o...

Страница 5: ...s for removal and re installation of the product The Federal Signal Corporation warranty shall not apply to components or accessories that have a separate warranty by the original manufacturer such as but not limited to batteries Federal will provide on site warranty service during the first 60 days after the completion of the installation when Federal has provided a turn key installation includin...

Страница 6: ...G Read and understand the information contained in this manual before attempting to install or service the siren Pay careful attention to the following notices located on the equipment NOTICES EXTERNALLY PLACED ...

Страница 7: ... Siren Description 1 1 4 Signal Description 1 SECTION II SPECIFICATIONS 2 1 Specifications 2 SECTION III INSTALLATION 3 1 Siren Location 3 3 2 Siren Installation 4 3 3 Siren Wiring 6 3 4 Pre operation Checkout 8 SECTION IV SERVICE AND MAINTENANCE 4 1 General 9 4 2 Inspection 9 4 3 Corrective Maintenance 10 ...

Страница 8: ...y to the siren from a 208 220 or 240 optionally 480VAC line Two motors are used to create the siren signals One motor rotates the siren assembly The second motor which produces the sound energy is attached to a stator with a rotor mounted on the motor shaft concentric to the stator The rotor and stator each contain one row of ports As the motor rotates the rotor air is drawn into the rotor and pas...

Страница 9: ...Y 790Hz N A WAIL 470 790Hz 10 sec FAST WAIL 600 790Hz 3 6 sec Signal Duration 3 min programmable Sound Output SPL 130dBc 1dBc on axis at 100 30 5m Rotation 3 RPM Dimensions HWD 62 x 37 x 41 1574mm x 940mm x 1041mm Shipping Weight 450 pounds 204kg Siren Weight 420 pounds 191kg Operating Temperature 30 C to 60ºC Power requirements refers to the power supplied by the batteries or optional AC operatio...

Страница 10: ...iren Optimum sound propagation conditions exist when there are no obstructions in the sound path the terrain is flat and the air is calm Under these conditions each time the distance from the siren is doubled the sound level decreases by approximately 10dB For example the sound level at 100 feet 30 5m from a 2001 130 siren is 130dB At 200 feet 61m the level drops to 120dB at 400 feet 122m the soun...

Страница 11: ... possible to install a siren in almost any situation If the installations in this paragraph are not suitable modification of one of the configurations may be practical A siren is typically installed 40 50 ft above the ground If the installation is located less than 40 ft above the ground the sound intensity at close range may increase but at the same time the effective range of the siren may be re...

Страница 12: ... WARNING above 4 Raise the siren to the necessary height and lower it over the pole 5 Adjust the legs and insert shims if necessary between the siren legs and pole The legs adjust to a diameter between 7 53 and 12 25 See Figure 3 3 Bolt the siren to the pole using two 5 8 galvanized lag bolts with washers and split lockwashers per leg At least four inches of lag bolt must be screwed into the pole ...

Страница 13: ...ended install location Locate the platform at the siren installation site The platform must be properly anchored to the mounting surface WARNING The hoisting bracket does not have sufficient strength to support the combined weight of the siren and a platform Therefore do NOT lift the siren and platform together using the bracket as a lifting point 2 Hoist the siren to the installation site using t...

Страница 14: ...t of the controller provides positive power to the rotator motor One 2 AWG black wire provides a common 48VDC negative ground between the ground plane of the control cabinet and siren motors See Figure 3 6 for the wire connections in the 2001 130 Consult the manual for the controller being utilized to connect the wires from the head Figure 3 6 Wiring for Rotator Motor All wire connections should b...

Страница 15: ... tests or maintenance on the siren A Make sure that all air intakes and sound outlets are not obstructed B Make sure all connections in the Control Unit Battery Box are correct and properly tightened C Activate all siren tones to verify they are operating properly The siren should remain rotating during all alert tones D After the installation is complete and it has been established that the siren...

Страница 16: ... Battery Box before inspecting or maintaining the siren 4 2 INSPECTION Test the 2001 130 siren for proper operation at least once a month A daily test at noon curfew or other selected time is preferred This not only enhances the usefulness of the siren but also instills public confidence in the reliability of the warning system In order to minimize the possibility of siren failure annual inspectio...

Страница 17: ...ing However after the horn is moving the scale indication should decrease to some force within the specified range If the scale does not indicate between 25 and 30 pounds 11 and 13kg the drive band requires adjustment 2 To adjust the drive band a Perform steps a b and c in paragraph 4 3 A 1 above to determine if a drive band adjustment is necessary b Ensure that power to the siren is disconnected ...

Страница 18: ... Brush Holder Assy 5 Insert the replacement brush into the brush holder Connect the lead wires to the brush holder C Collector Ring Removal 1 Remove the brush assembly as described above 2 Disconnect the three wires from the terminal block TB5 inside the rotator housing and begin feeding wires up into the siren shaft see Figure 4 2 3 Federal suggests that the rotator drive band be loosened as desc...

Страница 19: ...tor housing assembly 14 Replace the back panel D Rotator Motor Replacement 1 Remove the two rotator housing panels see Figure 4 2 2 Replace the rotator motor Approximately a 1 64 gap between the teeth of the two gears is required to avoid binding Re tighten rotator motor bolts to a torque of 45 in lbs 3 Wire rotator motor and terminal block as shown in Figure 3 6 4 Grease all gear surfaces with Mo...

Страница 20: ...13 Figure 4 9 2001 130 Final Assembly Sheet 1 ...

Страница 21: ...14 Figure 4 10 2001 130 Final Assembly Sheet 2 ...