INSTALLATION AND SERVICE INSTRUCTIONS FOR FEDERAL MODEL 121X  

SERIES C 120 Vac AND 24 Vdc EXPLOSION-PROOF LIGHT

SAFETY MESSAGE TO INSTALLERS

It is important to follow all instructions shipped with this product. This device is to be 
installed by a trained electrician who is thoroughly familiar with the National Electri-
cal Code and will follow the NEC Guidelines as well as local codes.

The selection of the mounting location for the device, its controls and the routing of the 
wiring is to be accomplished under the direction of the facilities engineer and the safety 
engineer. In addition, listed below are some other important safety instructions and 
precautions you should follow:

•  Read and understand all instructions before installing or operating this equipment.

•  Do not connect this light to the system when power is on.

•  After installation, ensure that all set screws and threaded joints are properly tight-

ened.

•  To prevent ignition of hazardous atmospheres, disconnect the fixture from the sup-

ply circuit before opening. Keep tightly closed when in operation.

•  After installation, test the light system to ensure that it is operating properly.

•  After testing is complete, provide a copy of this instruction sheet to all personnel.

•  Establish a procedure to routinely check the light system for proper activation and 

operation.

Failure to follow all safety precautions and instructions may result in property damage, 
serious injury, or death.

I. GENERAL

The Model 121X Light is an explosion-proof visual signaling device for hazardous 
locations and provides 90 flashes per minute. This light is UL listed for indoor and 
outdoor use.

This equipment is suitable for use in Class I, Div. 1, Groups C and D; Class II, Div. I, 
Groups E, F and G; Class III and non-hazardous locations.

These devices are intended for permanent installation and operation in accordance 
with Title 46, Code of Federal Regulations, Part 183, Sub-part I, Section 183.410, 
and the applicable requirements of the American Boat and Yacht Council, Inc., and/
or ANSI / NFPA 302, “Fire Protection Standard for Pleasure and Commercial Motor 
Craft.”

WARNING

EXPLOSION HAZARD—This light fixture is not backward compatible with 

older products. Do not use this light fixture with the Series A versions of 

model CMXC, CMXC-R, PMXC, PMXC-R, WMXC, or WMXC-R mounting acces-

sories. Failure to follow this warning may result in personal injury or death.

Содержание 121X Series

Страница 1: ...N DE 120VCA Y 24VCC MODELO 121X SERIE C MODEL 121X INSTALLATION AND SERVICE INSTRUCTIONS FOR MODEL 121X SERIES C 120 Vac AND 24 Vdc EXPLOSION PROOF LIGHT 25500043A REV A 413 Printed in U S A FEDERAL S...

Страница 2: ...the light system to ensure that it is operating properly After testing is complete provide a copy of this instruction sheet to all personnel Establish a procedure to routinely check the light system...

Страница 3: ...l au thority having jurisdiction For marine applications all wiring including supply wire must be stranded wire and meet the USCG CFR46 Section 110 113 A See Figure 1 Ensure that the mating threads ar...

Страница 4: ...instructions before operating this system Any maintenance to the light system must be done with power turned off Any maintenance to the light system must be performed by a trained electrician in accor...

Страница 5: ...ature before cleaning Fixture should be cleaned periodically to maintain maximum light output Only mild non abrasive cleaning agents should be used F The glass dome should be regularly inspected for s...

Страница 6: ...ed and give all pertinent information regarding the nature of the malfunction and if possible its cause F Replacement Parts Lamp Incandescent 24 Vdc K8107A041 Lamp Incandescent 120 Vac K8444A173 Glass...

Страница 7: ...esultar en da os a la propie dad lesiones serias o muerte a usted o terceras personas I GENERAL El Modelo 121X es un aparato de se al visual para reas peligrosas a prueba de explosi n Propor ciona 90...

Страница 8: ...ue de terminal marcado L Conecte el cable de alimentaci n negativo al tornillo del bloque de ter minal marcado N b Si los c digos de construcci n locales lo requieren conecte el cable de tierra al tor...

Страница 9: ...a o Las juntas del cuerpo o la cubierta deben ser reensambladas inmedia tamente uniendo todas las roscas 2 Afloje el tornillo del clip de lente 1 a 3 vueltas y gire la clavija 90 Quite el domo para de...

Страница 10: ...ederal Signal dar servicio a su equipo o proporcionar asistencia t cnica con cualquier problema que no pueda ser manejado localmente con satisfacci n y rapidez Cualquier unidad devuelta para ajuste o...

Страница 11: ...ves ou mortelles pour vous ou d autres I G N RALIT S Le mod le de lampe 121X est un dispositif de signalisation visuelle anti explosion pour les endroits dangereux et il fournit 90 clairs par minute C...

Страница 12: ...ux connectez le fil de terre la vis verte dans la monture 2 Lampes en Courant Alternatif ATTENTION Pour r duire les risques de choc pendant l entretien LA POLARIT DOIT TRE RESPEC T E quand on fait la...

Страница 13: ...ion ressort du d me de 1 3 tours et faire pivoter la fixation de 90 Retirer le d me pour exposer la lampe Pour retirer la lampe 120 V CA la d visser faire tourner dans le sens antihoraire pour la reti...

Страница 14: ...e E Service Federal Signal s occupe du service de votre mat riel ou fournit une assistance technique pour tout probl me qui ne peut tre trait localement Toutes les unit s renvoy es Federal Service pou...

Страница 15: ...de clip de lente D Clip de lente E L mpara F Lente G Tornillo de presi n H Conducto N P T 3 4 I Bloque terminal J Conjunto del mecanismo K Reflector L C pula de vidrio montaje M C pula de vidrio Fran...

Страница 16: ...desviada B Bloque terminal Fran ais A Ne convient pas pour utilisation avec conducteurs de d rivation de passage B Bloc de bornes 2 290A7010 A B Federal Signal Corporation Industrial Products 2645 Fed...

Страница 17: ......

Отзывы: