background image

Model C10 &

THIS WARRANTY DOES NOT COVER DAMAGE CAUSED BY: 

• Improper installation  
• Misuse of equipment 
• Negligent servicing 
• Improper applications 
• Preventative maintenance  
• Unauthorized modifications 
• Improper electrical supply
• Failure to follow manufacturer’s instructions and rating plate

information

• Accidents or other events beyond FEDDERS’ control

ENTIRE WARRANTY: 

THE ABOVE CONTAINS THE SOLE AND EXCLUSIVE
STATEMENT OF THE EXPRESS WARRANTIES AND
ASSOCIATED REMEDIES AVAILABLE WITH THE
PRODUCTS DESCRIBED. NO OTHER EXPRESS
WARRANTIES ARE MADE. ALL IMPLIED WARRANTIES,
INCLUDING BUT NOT LIMITED TO ANY IMPLIED
WARRANTY OF MERCHANTABILITY OR FITNESS FOR A
PARTICULAR PURPOSE, OR IMPLIED WARRANTIES
OTHERWISE ARISING FROM COURSE OF DEALING OR
USAGE OF TRADE ARE LIMITED IN DURATION TO ONE
YEAR FROM THE DATE OF ORIGINAL PURCHASE. IN NO
EVENT SHALL FEDDERS BE LIABLE FOR ANY INDIRECT,
INCIDENTAL OR CONSEQUENTIAL DAMAGES, EVEN IF
ADVISED IN ADVANCE OF THE POSSIBILITY OF SUCH
DAMAGES. NO WARRANTIES, EXPRESS OR IMPLIED,
ARE MADE TO ANY BUYER UPON RESALE.

SOME STATES DO NOT ALLOW LIMITATIONS ON HOW LONG
AN IMPLIED WARRANTY LASTS OR DO NOT ALLOW THE
EXCLUSION OR LIMITATION OF INCIDENTAL OR
CONSEQUENTIAL DAMAGES, SO THE ABOVE LIMITATIONS
MAY NOT APPLY TO YOU. THIS WARRANTY GIVES YOU
SPECIFIC LEGAL RIGHTS, AND YOU MAY ALSO HAVE OTHER
RIGHTS, WHICH MAY VARY FROM STATE TO STATE. NO
WARRANTIES ARE MADE FOR UNITS SOLD OUTSIDE THE
ABOVE STATED AREAS. YOUR DISTRIBUTOR OR FINAL
SELLER MAY PROVIDE A WARRANTY ON UNITS SOLD
OUTSIDE OF THESE AREAS.

LIMITED FIVE YEAR WARRANTY:

Fedders will provide a replacement part or component
that proves to be defective in material or workmanship.

WARRANTY LIMITATIONS: 

• Limited Warranty does not include allowances for labor

or travel expense connected with the installation of
parts, so furnished in this Limited Warranty or for field
repair, or servicing of the equipment, nor for
refrigerant used

• For warranty purposes the purchase date is established

by a proof of purchase. If a proof of purchase can not
be verified, then warranty period will be measured
from the date of manufacture plus 6 months.

• Cost of repair or replacement of consumable parts is

not covered under the terms of this warranty

• Replacement parts are warranted only for the balance

of the original warranty period

• Applies only to original installation and normal use and

service within the 48 contiguous United States, District
of Columbia and Canada 

• Applies to service performed by an authorized servicer.  

WARRANTY IS VOID IF:  

• Serial plate is defaced      
• Product has defect or damage due to product

alteration, connection to an improper electrical supply,
shipping and handling, fire, flood, lightning or other
conditions beyond the control of Fedders

• Product is not installed according to Fedders’

instructions and specifications

• Product is operated in a corrosive environment

containing concentrations of corrosive agents causing
deterioration of components    

• Product is operated with indoor unit or refrigerant

control device that does not meet Fedders’
specifications

• Product is moved from original installation site

OWNER’S RESPONSIBILITIES:

• Provide proof of purchase (sales receipt)
• Provide normal care and maintenance as outlined in

installation and operation manual

• Make product reasonably accessible for service
• Pay for freight, labor and travel expenses
• Pay for premium service costs for service outside

servicer’s normal business hours

• Pay for service calls related to product installation and

maintenance

7

LIMITED WARRANTY

The information in this manual supersedes and replaces the previous instruction/operation manual. Illustrations cover the general
appearance of the units at the time of publication and the manufacturer reserves the right to make changes in design and
construction at any time without notice.

For replacement parts please, consult the installing dealer or contractor.

Fedders Corporation 
505 Martinsville Rd. 
Liberty Corner, NJ 07938

REV. 8/06

23-23-0418N-013

Содержание Split System Air Conditioner

Страница 1: ...Braze Joints 3 Evacuation 3 Opening the Service Valve Step Valve 3 CONNECT REFRIGERANT PIPING 4 Precautions 4 Liquid Line Sizes 4 Suction Line Sizes 4 SUBCOOLING CHARGING 5 OPERATION INSTRUCTIONS 5 MAINTENANCE INSTRUCTIONS 5 CONDENSING UNIT NOMENCLATURE 6 LIMITED WARRANTY 7 NOTE THESE INSTRUCTIONS ARE INTENDED AS AN AID TO QUALIFIED SERVICE PERSONNEL FOR PROPER INSTALLATION ADJUSTMENT AND OPERATIO...

Страница 2: ... representations contained in the limited warranty CODES The installer SHALL comply with all local state and federal codes and or regulations pertaining to this type of equipment and its installation Such codes and or regulations should take precedence over any recommendations contained herein in lieu of local codes Installations SHALL be made in accordance with the National Electrical Code local ...

Страница 3: ...denser as close as possible to the evaporator will increase the system capacities by reducing the line set refrigerant pressure drop and will make the system less susceptible to liquid migrations due to less refrigerant charge 1 The installer shall check available power to make certain it matches the unit rating plate located inside control box cover and that constant voltage can be maintained to ...

Страница 4: ...d wire If thermostat is located more than 100 ft from unit as measured along the control voltage wires use No 16 AWG wire to avoid excessive voltage drop 3 All wiring must be NEC Class 1 and must be separated from incoming power leads Use furnace transformer fan coil transformer or accessory transformer for control power Note Use of available 24 volt accessories may exceed the minimum power requir...

Страница 5: ... with tubing When necessary use hanger straps which are 1 in wide and conform to shape of tubing insulation Isolate hanger straps from insulation by using metal sleeves bent to conform to shape of insulation Condensing units are available with pre charged sweat type copper connecting fittings Units are factory charged for 15 of line set tubing Adjust charge 0 65 oz per foot of variation from chart...

Страница 6: ...icensed Contractor for filter replacement schedules and instructions WARNING SERIOUS PERSONAL INJURY OR DEATH MAY RESULT IF WATER SPRAY IS DIRECTED TOWARD LIVE ELECTRICAL CONNECTIONS OR POWER SOURCES Model 5 SUB COOLING CHARGING Coils with TXVs should be charged 10 12 degrees or one degree of sub cooling For proper sub cooling readings a standard high side gauge is required for pressure readings U...

Страница 7: ... Hz 2 230 Volts 1 Phase 50 Hz 3 208 230 Volts 3 Phase 60 Hz 4 460 Volts 3 Phase 60 Hz 5 230 Volts 3 Phase 50 Hz 6 380 Volts 3 Phase 50 Hz C Air Conditoner CH Heat Pump A F Fedders Poduct Type Brand V Sweat Fitting Type D R 22 Refrigerant Z R 410A Refrigerant Variations Electrical Designation B 21 1 2 W x 21 1 2 D x H C 29 1 2 W x 29 1 2 D x H Chassis Size Nominal Capacity Series CONDENSING UNIT NO...

Страница 8: ...pment nor for refrigerant used For warranty purposes the purchase date is established by a proof of purchase If a proof of purchase can not be verified then warranty period will be measured from the date of manufacture plus 6 months Cost of repair or replacement of consumable parts is not covered under the terms of this warranty Replacement parts are warranted only for the balance of the original ...

Отзывы: