Physical installation

Final installation steps for all mounting locations

Install the saddle valve on the nearest cold water supply
pipe (see the instructions on the package). If applicable,
connect the saddle valve upstream of any type of water
softener.

After the saddle valve has been installed and 1/4” copper
tubing fitted to the valve, but before attaching the copper
tubing to the float and valve assembly, turn the saddle valve
to the open position and discharge the water into a bucket
or pan. This will allow the water to void the line of any
debris that may have accumulated during the installation
process. 

Attach the 1/4” copper tubing to the float and valve
assembly with the ferrule and compression nut (provided).

Caution: The float and valve assembly must not turn when
tightening the copper tubing compression fittings to the
humidifier water reservoir pan fitting.

• 

Turn the water supply on at the saddle valve.

Check the water level in the water reservoir pan to ensure
it is 1-1 1/2” deep.

IMPORTANT:

In installations where accidental overflow could cause water
damage, connect a drain hose from the humidifier water
reservoir pan overflow tube to a drain. Do NOT use a soldered
joint because the overflow tube will become heated and warp
the water reservoir pan.

1/4" Copper Tubing

Compression Nut

Ferrule

Saddle Valve

Humidifier Water 

Resivoir Pan

NOTE:

The following items are
located in the bag
identified:

“707 SM/STD Hardware Kit”:

Saddle valve assembly

Содержание Herrmidifier 707U

Страница 1: ...11 Maintenance 12 Unit Diagram and Parts List 14 Warranty Back cover Manual for Installation Operation Maintenance Duct Mount Centrifugal Atomizer Humidifier Table of Contents 256703 001 7 04 CAUTION...

Страница 2: ...into the home and heated When heated this air dries out and greatly increases its capacity to hold more moisture By using a humidifier a source of water is provided to satisfy this increased moisture...

Страница 3: ...turn the humidistat to the OFF position Sq Footage of Home 1000 1500 2000 2500 3000 4000 Tight Home GPD 0 5 3 0 5 0 7 5 10 0 14 5 Average Home GPD 5 0 10 0 14 0 19 0 23 5 33 0 Loose Home GPD 10 0 16...

Страница 4: ...at least six 6 linear feet preferably 10 feet upstream from any electronic air cleaner Failure to follow this recommendation can cause excessive nuisance arcing and or power supply failure If the duct...

Страница 5: ...rge nozzle should be at least two 2 feet below the ceiling and from a vertical wall along the side The discharge nozzle should be about six and a half 6 1 2 feet from the floor If this is not possible...

Страница 6: ...cturer s original warranty Remember to select a location that is readily accessible for periodic inspection and cleaning of your humidifier Allow a minimum of 2 clearance in front of the humidifier an...

Страница 7: ...position with 2 10 sheet metal screws and flat washers provided 10 The float and valve assembly have been factory adjusted to maintain 1 1 1 2 of water in the water reservoir pan at normal water pres...

Страница 8: ...II of the inside wall using a saber saw or equivalent Do NOT cut through the entire wall 8 Remove the template from the wall In the 6 5 16 diameter holes previously drilled into the inside wall insta...

Страница 9: ...sion nozzle provided will be 2 5 8 long PLUS the total wall thickness as determined in the previous step Cut the extension nozzle to length on the square end The opposite end of the extension nozzle i...

Страница 10: ...copper tubing to the float and valve assembly with the ferrule and compression nut provided Caution The float and valve assembly must not turn when tightening the copper tubing compression fittings to...

Страница 11: ...operation of the humidifier during the heating season 3 The humidifier will only operate when the furnace blower is in operation 4 It is recommended to install a humidistat provided with model 707U i...

Страница 12: ...hrow switch may be installed 4 Turn the humidistat to the highest level past 60 and the humidifier should begin to run The humidifier should stop when the humidistat is turned off 5 Set the furnace co...

Страница 13: ...ly therefore the frequency of cleaning the unit also varies During the heating season check for film or scale build up in the unit or any moving part Establish a proper cleaning schedule to ensure the...

Страница 14: ...Remove the pump from the end of the impeller shaft If the pump is stuck in the motor drive shaft run hot water over the end of the shaft for a few seconds to loosen the pump 8 Flush water through the...

Страница 15: ...SCREEN 6 1 1 D9P IMPELLER 7 1 1 M3 SCREW SET CUP 8 1 1 8A IMPELLER PUMP 9 4 4 90 VIBRATION DAMPER 10 1 1 35P CENTER PAN 11 4 4 23 CENTER PAN SUPPORT 12 2 2 27 DRIP TUBE 13 1 1 92P FLOAT VALVE ASM 14...

Страница 16: ...ders com Humidifiers which have been installed or become part of real estate cannot be returned CareCo will receive freight prepaid only removable parts or components of such defective humidifiers 6 T...

Отзывы: