background image

Warranty

Humidifier Limited Two Year Warranty

This limited warranty covers Herrmidifier Residential Type Humidifiers, excluding duct work, wiring and
installation. The manufacturer warrants that all new Herrmidifier Humidifiers are free from defects in material
and workmanship under normal, non-commercial use and service. The manufacturer will remedy any covered
defects if they appear within 24 months from the date of original installation as evidenced by proof of
purchase, subject to the terms and conditions of this Limited Two-Year Warranty stated below:

1.

THIS LIMITED TWO-YEAR WARRANTY is granted by CareCo, 415 W. Wabash Ave., P.O. Box 200,
Effingham, IL 62401.

2.

This warranty shall extend only to any non-commercial owner who has purchased the residential
humidifier other than for purposes of resale.

3.  All components are covered by this limited warranty except expendable items, such as evaporative pads,

media filter pads and nozzles.

4.

If, within the warranty period, any Herrmidifier residential humidifier unit or component requires
service, it must be performed by a competent heating and/or air conditioning contractor (preferably the
installing contractor). CareCo will not pay shipping charges or labor charges to remove or replace such
defective parts or components. If the part or component is found by inspection to contain such defective
material and workmanship it will be either repaired or exchanged free of charge at CareCo's option,
and returned freight collect.

5.

In order to obtain the benefits of this limited two-year warranty, the owner must notify the dealer or
distributor of any defect within 30 days of its discovery. If after reasonable time you have not received
an adequate response from the dealer or distributor, notify in writing 

CareCo Service Dept., 415

Wabash Ave., P.O. Box 200, Effingham, Illinois, 62401, or call 1-866-829-2440 or email 
[email protected]

. Humidifiers which have been installed or become part of real

estate cannot be returned. CareCo will receive, freight prepaid, only removable parts or components of
such defective humidifiers.

6.

This limited warranty does not apply to any part or component that is damaged in transit or in handling,
has been subject to misuse, neglect or accident; has not been installed, operated and serviced according
to Herrmidifier's instructions; has been operated beyond the factory rated capacity; or altered in any
such way that its performance is affected. There is no warranty due to neglect, alteration or ordinary
wear and tear. Herrmidifier's liability is limited to replacement of defective parts or components and
does not include the payment of the cost of labor charges to remove or replace such defective
components or parts.

7.

CareCo will not be responsible for loss of use of any product; loss of time, inconvenience, or any other
indirect, incidental or consequential damages with respect to person or property, whether as a result of
breach of warranty, neglect or otherwise. SOME STATES DO NOT ALLOW THE EXCLUSION OR
LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES, SO THE LIMITATION OR EXCLUSION IN THE
PRECEDING SENTENCE MAY NOT APPLY TO YOU.

8.

THIS WARRANTY GIVES YOU SPECIFIC RIGHTS, AND YOU MAY ALSO HAVE OTHER RIGHTS WHICH VARY
FROM STATE TO STATE.

9.  Any warranty by CareCo of merchantability, fitness for use or any other warranty (express, implied or

statutory), representation or guarantee other than those set forth herein, shall expire at the expiration
date of this express limited warranty. SOME STATES DO NOT ALLOW LIMITATIONS ON HOW LONG AN
IMPLIED WARRANTY LASTS, SO THE LIMITATION IN THE PRECEDING SENTENCE MAY NOT APPLY TO
YOU.

10. Herrmidifier reserves the right to make changes in the design and material of its products without

incurring any obligation to incorporate such changes in units completed on the effective date of such
change.

CareCo Service Dept., 

415 Wabash Ave., P.O. Box 200, Effingham, Illinois, 62401 

Phone: 1-866-829-2440

E-mail: [email protected]

Содержание Herrmidifier 356686-001C

Страница 1: ... 11 Maintenance 12 Unit Diagram and Parts List 14 Warranty Back cover Manual for Installation Operation Maintenance Duct Mount Centrifugal Atomizer Humidifier Table of Contents 256703 001 7 04 CAUTION Read installation operation and maintenance instructions carefully for safe operation Exercise the usual precautions when working with electricity 707U Model 356686 001C 115 60 1 707U UK Model 356686...

Страница 2: ...t into the home and heated When heated this air dries out and greatly increases its capacity to hold more moisture By using a humidifier a source of water is provided to satisfy this increased moisture holding capability rather than having it drawn from our body surface and the surrounding furnishings in the home A properly maintained and efficiently operating humidifier is a source of improved In...

Страница 3: ...r turn the humidistat to the OFF position Sq Footage of Home 1000 1500 2000 2500 3000 4000 Tight Home GPD 0 5 3 0 5 0 7 5 10 0 14 5 Average Home GPD 5 0 10 0 14 0 19 0 23 5 33 0 Loose Home GPD 10 0 16 5 24 0 30 5 37 5 51 5 The above calculations are for reference only and are based on the following Inside temperature 70 F 35 relative humidity Outside Temp 20 F 70 relative humidity 8 foot ceiling h...

Страница 4: ... at least six 6 linear feet preferably 10 feet upstream from any electronic air cleaner Failure to follow this recommendation can cause excessive nuisance arcing and or power supply failure If the duct seams inside the duct are not flat locate the humidifier at least three 3 linear feet upstream from the seam If the humidification needs of the home require more than one humidifier each unit should...

Страница 5: ...arge nozzle should be at least two 2 feet below the ceiling and from a vertical wall along the side The discharge nozzle should be about six and a half 6 1 2 feet from the floor If this is not possible locate the humidifier in the area of least traffic The humidifier should be located between wall studs to facilitate cutting the discharge hole through the wall No obstructions should be directly in...

Страница 6: ...acturer s original warranty Remember to select a location that is readily accessible for periodic inspection and cleaning of your humidifier Allow a minimum of 2 clearance in front of the humidifier and 2 below the water pan to allow for maintenance and repair Prior to installing this product Read the instructions carefully to ensure safe operation Failure to follow them could damage the product o...

Страница 7: ...s position with 2 10 sheet metal screws and flat washers provided 10 The float and valve assembly have been factory adjusted to maintain 1 1 1 2 of water in the water reservoir pan at normal water pressure If necessary bend the float arm to the required position to maintain the water level at other water pressures 11 Before mounting the humidifier in its final position carefully rotate the impelle...

Страница 8: ...a II of the inside wall using a saber saw or equivalent Do NOT cut through the entire wall 8 Remove the template from the wall In the 6 5 16 diameter holes previously drilled into the inside wall install the 6 anchor bolts provided Remove each one of the bolts and mount the wire mounting bracket to the wall with 6 removed bolts and flat washers 9 The float and valve assembly have been factory adju...

Страница 9: ...nsion nozzle provided will be 2 5 8 long PLUS the total wall thickness as determined in the previous step Cut the extension nozzle to length on the square end The opposite end of the extension nozzle is angled to provide the correct fit with the outside wall 15 Fit the flexible connector sleeve onto the discharge dome and fasten securely with one 1 hose clamp provided 16 Insert the angle cut end o...

Страница 10: ... copper tubing to the float and valve assembly with the ferrule and compression nut provided Caution The float and valve assembly must not turn when tightening the copper tubing compression fittings to the humidifier water reservoir pan fitting Turn the water supply on at the saddle valve Check the water level in the water reservoir pan to ensure it is 1 1 1 2 deep IMPORTANT In installations where...

Страница 11: ...c operation of the humidifier during the heating season 3 The humidifier will only operate when the furnace blower is in operation 4 It is recommended to install a humidistat provided with model 707U in the system to provide optimum performance when continuous air circulation is desired 5 If a humidistat is not used in the installation install an ON OFF switch in its place This provides a simple y...

Страница 12: ...throw switch may be installed 4 Turn the humidistat to the highest level past 60 and the humidifier should begin to run The humidifier should stop when the humidistat is turned off 5 Set the furnace controls and humidistat for the desired conditions 30 40 RH is recommended Operation of this unit is automatic 6 If condensation occurs on single pane windows lower the humidistat setting until the con...

Страница 13: ...tly therefore the frequency of cleaning the unit also varies During the heating season check for film or scale build up in the unit or any moving part Establish a proper cleaning schedule to ensure the efficiency of the humidifier An algaecide such as a humidifier cleaning tablet or bacteriostatic liquid powder can be used to combat algae build up should it become evident At the end of the winter ...

Страница 14: ...7 Remove the pump from the end of the impeller shaft If the pump is stuck in the motor drive shaft run hot water over the end of the shaft for a few seconds to loosen the pump 8 Flush water through the impeller tube ensuring that the six holes at the top of the impeller tube are open and clear of mineral deposits A pipe cleaner works well for this cleaning operation Note The impeller tube and pump...

Страница 15: ...G SCREEN 6 1 1 D9P IMPELLER 7 1 1 M3 SCREW SET CUP 8 1 1 8A IMPELLER PUMP 9 4 4 90 VIBRATION DAMPER 10 1 1 35P CENTER PAN 11 4 4 23 CENTER PAN SUPPORT 12 2 2 27 DRIP TUBE 13 1 1 92P FLOAT VALVE ASM 14 1 1 47BP PAN 15 1 252596 001 MOTOR 115 VOLT 15A 1 252596 002 MOTOR 220 VOLT 16 1 1 186 MOUNTING BRACKET 17 1 53 EXTENSION NOZZLE NI 1 3526BO 002C HUMIDISTAT NI 1 1 IN 2ST SADDLE VALVE NI 1 54 BEZEL N...

Страница 16: ...dders com Humidifiers which have been installed or become part of real estate cannot be returned CareCo will receive freight prepaid only removable parts or components of such defective humidifiers 6 This limited warranty does not apply to any part or component that is damaged in transit or in handling has been subject to misuse neglect or accident has not been installed operated and serviced acco...

Отзывы: