ELECTRONIC CONTROLS

OPERATION

Electronic Control Panel

Power Control

The Power Control turns the unit on and off.

Set Temperature/ Timer Display

Shows the set temperature when the unit is in operation and hours
when the timer is being set. 

THE TEMPERATURE DISPLAY ONLY

SHOWS THE SET TEMPERATURE, NOT THE ACTUAL ROOM
TEMPERATURE.

Temperature/ Timer Hour Controls

These buttons are used to raise or lower the set temperature in
increments of 1° from 66° to 88°. By depressing both buttons at once,
the display will toggle between Celsius and Fahrenheit. When the
timer is being set, these buttons are used to change the hour setting in
increments of 1 from 00 to 24.

Mode Control

A green light will indicate which mode is currently being utilized.

Cool Mode –

The unit will circulate and cool the air.

Fan Mode –

The unit will only circulate the air.

Energy Saver Mode –

The fan will switch from the set fan speed to LOW whenever the
compressor turns off in response to the thermostat. When the
compressor cycles back on, the unit will return to the original fan
setting. 

Fan Speed Control

High, Medium, Low and Auto

The settings are adjusted with the Fan Speed Control, each time the
button is depressed it changes the setting. A green light will indicate
which setting is currently being used.
When the AUTO feature is selected while the air conditioner is in the
COOL or HEAT mode, the fan speeds will change automatically as
the temperature in the room changes.

• 7° or more above the set temperature will use HIGH FAN.
• 4° – 7° above the set temperature will use MED FAN.
• 4° or less above the set temperature will use LOW FAN.

Timer Control

The timer can be set to either turn the unit on or off.

To turn the unit on using the Timer:

Depress the timer key when the power is off, the display will read 00.
Adjust to the desired number of hours before TURN ON using the
up/down arrows.
The display will show the time by hours left until TURN ON.
To Turn the timer off, depress the timer key.
A green light next to the Timer Control indicates that the timer is set.

To turn the unit OFF using the Timer:

Depress the timer key when the power is on, the display will read 00.
Adjust to the desired number of hours before TURN OFF using the
up/down arrows. The display will automatically go back to the set
temperature after 10 seconds.

To display the amount of time left until TURN OFF, depress the timer
button once.

To turn the TIMER OFF, depress the timer button twice.

A green light next to the Timer Control indicates that the timer is set. 

Air Exchanger

Circulates fresh air and helps remove stale air when in the open
position. Maximum air circulation and cooling occur when in the
closed position.

Built-in three minute timing delay.

If this electronic unit will not respond to touch pad or remote control
commands, it is necessary to unplug the unit from the electrical outlet
for five seconds and then plug the unit back in.

Auto restart feature:

In the event of a power failure, this feature allows the unit to

resume operation once power has been restored, retaining the

most recent settings. Upon restoration of power, the timer

mode may need to be reset if being utilized 

The functions work the same as your air conditioner’s touch controls.

Air Conditioner Remote Control 

D

G

G

E

F

A

C

C

D

E

F

A

B

B

AAA

IEC R03

1.5V

+

-

AAA

IEC R03

1.5V

CAUTION

• Use only AAA or IEC R03 1.5V batteries.
• Remove the batteries if the remote controller is not used for a month

or longer.

• Do not attempt to recharge the supplied batteries
• All batteries should be replaced at the same time.
• Do not dispose of the batteries in a fire as they may explode.
• Do not mix old and new batteries.
• Do not mix alkaline, standard (carbon - zinc), or rechargeable

(nickel-cadmium) batteries.

• Do not install the batteries with the polarity (+/–) reversed.
• Keep batteries and other things that could be swallowed away from

young children. Contact a doctor immediately if an object is
swallowed.

Содержание A6V05S2B

Страница 1: ... Use these numbers in any correspondence or service calls concerning your air conditioner Para referencia futura Escriba el número de modelo y de serie El número de modelo y de serie se encuentran en el costado del gabinete Use estos números en toda la correspondencia o llamadas de servicio relacionadas con su acondicionador de aire Pour consultation ultérieure Inscrivez les numéros de modèle et d...

Страница 2: ...no other device or unit should be operated on that fuse or circuit breaker We recommend that a qualified electrician install unit in accordance with the National Electrical Code and local codes and ordinances Use copper conductors of correct wire gauge and protector size only Do not alter cord or plug end Do not remove warning label on cord Important Grounding Requirements Air conditioner has a th...

Страница 3: ...ee 3 3 8 long self tapping screws Fig 3 4 Loosely attach support angle to bottom of support platform using two 2 7 16 long machine screws flat washers and nuts 5 Place support platform against lower window track and firmly against vertical edge of window frame Fig 4 6 Attach support platform to window sill using two 2 1 long self tapping screws Fig 4 If required overcome interference of support pl...

Страница 4: ...s through these holes If window channel frame is not tall enough to use existing holes drill 2 new holes off to the side of the existing holes to attach the unit bottom bar to the support platform Unit should be firmly anchored to window channel frame or support platform Fig 6 12 Slide inside window sash closed Be sure vertical edge of inside window sash is pressed firmly against side of unit cabi...

Страница 5: ...ecessary to construct a frame using at least 1 thick wood with a 15 1 2 wide opening 2 Paint frame and fasten it securely sealing it into window opening 3 Install unit into frame following procedures for metal sliding and casement windows These installations are also typical and since styles and sizes of casement windows vary widely it is advisable to have unit installed by someone skilled in this...

Страница 6: ...rows The display will show the time by hours left until TURN ON To Turn the timer off depress the timer key A green light next to the Timer Control indicates that the timer is set To turn the unit OFF using the Timer Depress the timer key when the power is on the display will read 00 Adjust to the desired number of hours before TURN OFF using the up down arrows The display will automatically go ba...

Страница 7: ...aller Water dripping inside Improper installation Tilt air conditioner slightly to the outside to when unit is cooling allow water drainage Refer to installation instructions check with installer Water dripping outside Unit removing large quantity of moisture This is normal during excessively humid days when unit is cooling from humid room Insufficient Cooling Shut all windows and doors in room Re...

Страница 8: ...HALL FEDDERS BE LIABLE FOR INDIRECT INCIDENTAL OR CONSEQUENTIAL DAMAGES EVEN IF ADVISED IN ADVANCE OF THE POSSIBILITY OF SUCH DAMAGES NO WARRANTIES EXPRESS OR IMPLIED ARE MADE TO ANY BUYER UPON RESALE Some states do not allow limitations on how long an implied warranty lasts or do not allow the exclusion or limitation of incidental or consequential damages so the above limitations or exclusions ma...

Страница 9: ...cia el exterior con arbustos recintos u otros edificios No haga funcionar el acondicionador de aire teniendo instalada la cubierta protectora exterior Esto podría resultar en daño mecánico dentro del acondicionador de aire ADVERTENCIA 250V 30A 250V 15A 125V 15A 250V 20A ADVERTENCIA ADVERTENCIA No retire o modifique este enchufe No lo utilice como un interruptor de encendido apagado No lo use en el...

Страница 10: ...mente contra el borde vertical del marco de la ventana Fig 4 6 Fijar la plataforma de soporte al alfêizar o tablilla de la ventana usando dos 2 tornillos de 1 de largo Fig 4 Para superar la interferencia de la plataforma de soporte con el canal de la ventana o la contraventana sujete fijamente una cuña de madera de 2 de ancho al alfêizar o tablilla de la ventana La franja de madera debera ser tan ...

Страница 11: ...d debe estar firmemente sujeta al canal del marco de la ventana o a la plataforma de soporte Fig 6 12 Deslice el bastidor interior de la ventana cerrada Cerciórese de que el borde vertical del bastidor interior de la ventana esté firmemente apoyado contra el costado del gabinete de la unidad Corte el resto del sellador de espuma con respaldo adhesivo del mismo ancho de la abertura de la ventana Re...

Страница 12: ... de por lo menos una pulgada de espesor con una abertura de 15 1 2 de ancho 2 Pinte el marco y sujételo firmemente sellándolo en la abertura de la ventana 3 Instale la unidad en el marco siguiendo los procedimientos indicados para ventanas metálicas y de hoja batiente Estas instalaciones son típicas debido a que los estilos y tamaños de las ventanas batientes varían considerablemente se recomienda...

Страница 13: ...temporizador Presione la tecla del temporizador cuando el suministro de energía esté apagado la pantalla leerá 00 Ajuste al número deseado de horas antes que SE PRENDA usando las flechas de arriba abajo La pantalla mostrará el tiempo por horas que faltan para que SE PRENDA Para apagar el temporizador presione la tecla del temporizador Una luz verde junto al control del temporizador indica que se h...

Страница 14: ...stá enfriando Causa Posible El enchufe mural está desconectado Se ha fundido un fusible o se ha disparado el disyuntor El acondicionador de aire se apagó y luego se encendió demasiado rápidamente El ajuste del termostato es muy bajo para enfriamiento El control de modo está en la posición Fan Ventilador El termostato está en un ajuste demasiado caliente La temperatura de la habitación es inferior ...

Страница 15: ...del uso normal del producto Es responsabilidad del propietario facilitar el acceso al acondicionador de aire para realizar los servicios de reparación Nota En caso de que se requiera reemplazar una pieza mientras la garantía está vigente se utilizarán los repuestos de Fedders los cuales continuarán en vignecia solamente durante el resto del período de garantía de la unidad Excepciones La garantía ...

Страница 16: ...n propre fusible ou disjoncteur et aucun autre appareil ne devrait être branché sur le même circuit d alimentation Il est recommandé qu un électricien qualifié installe l appareil conformément aux prescriptions du code national des installations électriques et des codes et règlements locaux applicables Utiliser uniquement des conducteurs en cuivre et dispositifs de protection de calibre et de capa...

Страница 17: ...enêtre à l aide de deux 2 vis autotaraudeuses de 1 po de longueur Fig 4 Pour empêcher que cette plate forme n empiète sur la glissière de la fenêtre coulissante ou la contre fenêtre attacher solidement une entretoise de 2 po de largeur à l appui de fenêtre La longueur de cette entretoise devrait être égale à la largeur de la plate forme de support et son chant devrait être aligné sur la rive arriè...

Страница 18: ...é au cadre de fenêtre ou à la plate forme de support Fig 6 12 Faire glisser la fenêtre intérieure pour la fermer S assurer que le bord vertical de la fenêtre intérieure est appuyé fermement contre le côté du boîtier de l appareil Couper le joint de mousse à dos adhésif restant à la largeur de l ouverture de la fenêtre Enlever le dos protecteur et appliquer sur le bord intérieur supérieur du cadre ...

Страница 19: ...ec ouverture d une largeur de 15 1 2 po 2 Peindre le cadre et le fixer solidement en le scellant dans l ouverture de fenêtre 3 Poser l appareil dans le cadre en suivant les instructions données pour les fenêtres à battants et les fenêtres coulissantes métalliques Puisque le style et la grandeur de chaque fenêtre et le type d installation varient énormément il est recommandé que ce dispositif soit ...

Страница 20: ...dessus de la température réglée l appareil utilisera la vitesse de ventilation moyenne ou MED FAN À 4 degrés ou moins au dessus de la température réglée l appareil utilisera la vitesse de ventilation faible ou LO FAN Commande de la minuterie On peut régler la minuterie afin de mettre l appareil en marche ou de l arrêter Pour mettre l appareil en marche au moyen de la minuterie alors que l appareil...

Страница 21: ...dité Vibration de la fenêtre installation médiocre Installation incorrecte Extraction d une grande quantité d humidité dans la pièce par l appareil Solutions Enfoncer fermement la fiche dans la prise de courant murale Remplacer le fusible par un fusible temporisé ou réarmer le disjoncteur Après un arrêt du climatiseur attendre 3 minutes avant la remise en marche Modifier le réglage du thermostat p...

Страница 22: ...PRESSE OU IMPLICITE N EST OFFERTE À UN ACHETEUR QUELCONQUE EN CAS DE REVENTE Certains états n autorisent pas les limitations de durée des garanties tacites ni les exclusions ou limitations frappant les dommages accessoires ou indirects Il se peut donc que les exclusions ou limitations susmentionnées ne vous soient pas opposables La présente garantie vous confère des droits précis vous pouvez égale...

Страница 23: ......

Страница 24: ...ntilación ajustables Claires voies orientables Cabinet Gabinete Caisse Filler Panel Panel de Relleno Panneau de remplissage Top Bar Barra Superior Tringle supérieure Power Cord Cordón Le cordon d alimentation 23 23 0303N 007 Features and specifications subject to change without notice Las características y especificaciones están sujetas a cambio sin previo aviso Les caractéristiques et spécificati...

Отзывы: