MSD
TM
Series
© Copyright 2018 Fluid Equipment Development Company | www.fedco-usa.com
-
43
-
Pump Assembly Continued
12. Slide the dropout coupling against the
dropout hub leaving a small space between
the end of the motor shaft and the coupling
spacer (approximately 1/8”).
Figure 81 - Install Dropout Coupling On Motor
Shaft
Figure 80 - Install Dropout Coupling On Pump
Shaft
10. After dial indication and adjustments have
been made, reinstall the coupling hubs.
11.
The pump shaft end should be inset ap
-
proximately 1/8” away from the end of the
pump hub.
Figure 79 -
Shaft Alignment With Indicator
8.
With dial indicator base secured to motor
shaft, sweep face of pump inlet as well as
inner bore of MSD inlet.
9. Make adjustments as necessary. See
Initial
Pump Alignment
section for details.
NOTES:
Indicate on machined surfaces only.